46 - PVD 3674_GB_K Series_CE-November 2016.Docx
3.5. Natural cooled motor
In compliance with the IEC 60034-1 standards: the ambient air temperature shall not
be less than
-15°C
and more than
40°C.
K Series Kit are housed in a motor frame detailled in § 3.4.4.1 Stator
Warning: To reach the motor performances calculated, the complete
motor must thermally well connected to a aluminium flange with the
following dimensions:
-
K032
: 25.4 cm×25.4 cm×0.635 cm (S=1355 cm²)
-
K044
: 25.4 cm×25.4 cm×0.635 cm (S=1355 cm²)
-
K064
: 25.4 cm×25.4 cm×0.635 cm (S=1355 cm²)
-
K089
: 30.48 cm×30.48 cm×1.27 cm (S=2013 cm²)
-
K178
: 40.64 cm×40.64 cm×2.54cm (S=3716 cm²)
Caution: the ambient air temperature shall not exceed 40°C in the
vicinity of the motor flange
Warning: A significant part of the heat produced by the motor is
evacuated through the flange.
if the air is not able to circulate freely around the motor,
if the motor is mounted on a surface that dissipates not well the
heating (surface with little dimensions for instance),
if the motor is thermally isolated,
if the motor is mounted on a warm surface (mounted on a gearbox
for instance),
then the motor has to be used at a torque less than the rated torque.
Summary of Contents for K Series
Page 8: ...8 PVD 3674_GB_K Series_CE November 2016 Docx 2 4 Motor description ...
Page 26: ...26 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 Dimension drawings 3 3 1 K032 Stator ...
Page 27: ...27 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 2 K032 Rotor ...
Page 28: ...28 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 3 K032 Stator with Hall effect sensor ...
Page 30: ...30 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 5 K044 ...
Page 31: ...31 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 6 K044 with Hall effect sensor ...
Page 32: ...32 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 7 K064 ...
Page 33: ...33 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 8 K064 with Hall effect sensor ...
Page 34: ...34 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 9 K089 ...
Page 35: ...35 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 10 K089 with Hall effect sensor ...
Page 36: ...36 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 11 K178 ...
Page 56: ...56 PVD 3674_GB_K Series_CE November 2016 Docx Resolver part number 220005P1003 ...