Minimum clearances for insulation:
Voltage rms
Required
impulse
withstand
voltage
V
Minimum clearances in air in millimeters up to 2000 m above sea level
Case A
(inhomogeneous field)
Case B
(homogeneous field)
Pollution degree
Pollution degree
1
mm
2
mm
3
mm
4
mm
1
mm
2
mm
3
mm
4
mm
50V
600
0,06
0,2
0,8
1,6
0,06
0,2
0,8
1,6
from 100V to 250V
1500
0,5
0,5
0,8
1,6
0,3
0,3
0,8
1,6
up to 500V
2000
1
1
1
1,6
0,45
0,45
8
1,6
N.B. Please refer to the standard EN 60664-1 for more information.
Minimum creepage distances for equipment subject to long-term stresses
Voltage
rms
Creepage distances in millimeters
Pollution degree
1
2
Material group
3
Material group
4
Material group
mm
I
mm
II
mm
III
mm
I
mm
II
mm
III
mm
I
mm
II
mm
III
mm
50
0,18
0,6
0,85
1,2
1,5
1,7
1,9
2
2,5
3,2
100
0,25
0,71
1
1,4
1,8
2
2,2
2,4
3
3,8
160
0,32
0,8
1,1
1,6
2
2,2
2,5
3,2
4
5
200
0,42
1
1,4
2
2,5
2,8
3,2
4
5
6,3
250
0,56
1,25
1,8
2,5
3,2
3,6
4
5
6,3
8
320
0,75
1,6
2,2
3,2
4
4,5
5
6,3
8
10
400
1
2
2,8
4
5
5,6
6,3
8
10
12,5
500
1,3
2,5
3,6
5
6,3
7
8
10
12,5
16
N.B. Please refer to the standard EN 60664-1 for more information.
3.4.9.
Ground continuity compliance
The Motors must meet the standards IEC 60204-1.
Continuity of the grounding circuit : On each complete unit, the resistance between
any conductive point and the grounding conductor shall not exeed than100 m
. This
test shall be performed before the dielectric tests. (EN 60204-1: Safety of the
machine)
3.4.10.
Protection rating
cf. IEC 60529 and IEC 60034-5
The K Series Kit Motors show an IP00 protection rating. It is the integrator's
responsibility to ensure the appropriate protection rating depending on the use of the
motor (protection against electric shocks of persons, protection against dust, liquids,
solid particles
, …
Summary of Contents for K Series
Page 8: ...8 PVD 3674_GB_K Series_CE November 2016 Docx 2 4 Motor description ...
Page 26: ...26 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 Dimension drawings 3 3 1 K032 Stator ...
Page 27: ...27 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 2 K032 Rotor ...
Page 28: ...28 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 3 K032 Stator with Hall effect sensor ...
Page 30: ...30 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 5 K044 ...
Page 31: ...31 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 6 K044 with Hall effect sensor ...
Page 32: ...32 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 7 K064 ...
Page 33: ...33 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 8 K064 with Hall effect sensor ...
Page 34: ...34 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 9 K089 ...
Page 35: ...35 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 10 K089 with Hall effect sensor ...
Page 36: ...36 PVD 3674_GB_K Series_CE November 2016 Docx 3 3 11 K178 ...
Page 56: ...56 PVD 3674_GB_K Series_CE November 2016 Docx Resolver part number 220005P1003 ...