![Parker IQAN-XA2 Instruction Book Download Page 31](http://html1.mh-extra.com/html/parker/iqan-xa2/iqan-xa2_instruction-book_4039136031.webp)
29
IQAN-XA2 Technical Overview
Appendix A
Instruction book, IQAN-XA2
Power driver, DOUT (on/off output)
Number of DOUT
12
Maximum load
2 A
Power driver voltage drop
typ. 0.
3
0 V @ 1.5 A load
Leakage current in OFF state
DOUT-A to DOUT-F
DOUT-G to DOUT-L
<100 uA
<1 mA
Maximum load inductance
V
BAT
= 14 V, single pulse
V
BAT
= 2
8
V, single pulse
PWM (incl.
S
oftstart,
S
oftstop)
14 Ohm /
3
66 mH, 9.
3
ohm / 126 mH, 7 ohm / 50 mH
2
8
Ohm /
33
4 mH, 19 ohm / 114 mH, 14 ohm / 46 mH
external clamping diode is mandatory
Protection
over load,
S
CB,
S
CG
Diagnostics no
CAN
T
A
= -40 °C to +70 °C (unless otherwise specified)
Parameter
Remark
Number of CAN buses
1
CAN specification
2.0A and 2.0B
CAN bus speed
250 kbit
Protection
S
CB,
S
CG
I/O
T
A
= -40 °C to +70 °C (unless otherwise specified)
Parameter
Remark