![Parker IQAN-XA2 Instruction Book Download Page 29](http://html1.mh-extra.com/html/parker/iqan-xa2/iqan-xa2_instruction-book_4039136029.webp)
27
IQAN-XA2 Technical Overview
Appendix A
Instruction book, IQAN-XA2
Maximum load current
150 mA
Protection
overload,
S
CB,
S
CG
Diagnostics
over/under voltage
Under/over voltage threshold
±250 mV from nominal value
I/O
T
A
= -40 °C to +70 °C (unless otherwise specified)
Parameter
Remark
VIN (Voltage input)
Number of VIN
8
(configuration may reduce number)
VIN full scale
5000 mV ±100 mV
VIN resolution
10 bits = 5 mV
Input impedance
62 kohm pull-down in parallel with 470 pF
Accuracy
with external sensor supply
with VREF sensor supply
±100 mV
±
3
5 mV
Protection
S
CB,
S
CG
Diagnostics
Defined in application
DIN (On/off input)
Number of DIN
20 (configuration may reduce number)
Logic levels
low
high
<1 V
>4 V
Input hysteresis
DIN-A to DIN-H
DIN-I to DIN-T
typ. 1.0 V
typ. 0.5 V
Input impedance
DIN-A to DIN-H
DIN-I to DIN-T
62 kohm pull-down in parallel with 470 pF
5.6 kohm pull-down in parallel with 10 pF
Diagnostics
Defined in application
FIN (Frequency input) / DFIN (Directional Frequency input)
Number of FIN / DFIN
2 / 1 (configuration may reduce number)
Frequency range
FIN
DFIN
2 to
3
0,000 Hz(>20 Hz in Fast response)
2 to
3
0,000 Hz(>20 Hz in Fast response
Minimum pulse width
TBD for 5 V signal
S
tep response
500 ms, 10% to 90% step
Logic levels
low
high
<1 V
>4 V
Input hysteresis
typ. 1.0V
Input impedance
62 kohm pull-down in parallel with 470 pF
Diagnostics
Defined in application
Sensor supply, VREF
T
A
= -40 °C to +70 °C (unless otherwise specified)
Parameter
Remark