![Parker IQAN-LC6-X05 Instruction Book Download Page 16](http://html.mh-extra.com/html/parker/iqan-lc6-x05/iqan-lc6-x05_instruction-book_756311016.webp)
14
Output signals
6 Installation
Instruction book, IQAN- LC6-X05
Output signals
Primary and secondary outputs
The IQAN-LC6-X05 has two sensors for each axis that have thier output signals
mirrored. The two outputs allow the user to set up controller logic that monitors the
integrity of the two joystick signals to ensure that the joystick is operating properly. It
is possible to use only one signal but it is recomended to use both.
Connecting of IQAN-LC6-X05 base outputs
When you connect the IQAN-LC6-X05 joystick to a module or standalone controller,
you should use both primary and secondary signals from the joystick. The primary
signal for the axis is connected to a VIN,
voltage input
and the secondary signal for the
axis is connected to a separate VIN on the controller module.
Connect each primary axis 10%-90% Vs output signal to VIN, and connect the
corresponding secondary axis 90%-10% Vs output signal to another VIN.
W
ARNING
The previous example is presented with limited information to explain the use of
primary and secondary signals from the IQAN-LC6-X05. Safety considerations such as
the use of an ’operator present’ switch to enable outputs etc. are always recommended.
EXAMPLE
Connecting an IQAN-LC6-X05 to a module.
to valve section controlled
to valve section controlled
VOUT-YB
VOUT-XB
VOUT-XA
VOUT-YA
by Y axis of joystick
by X axis of joystick
IQAN module
LC6-X05
VIN
VIN
VIN
VIN