19
IQAN-G2 Technical Overview
Appendix A
Instruction book, IQAN-G2
Appendix A
IQAN-G2 Technical Overview
Absolute Maximum Ratings
a
a.The “Absolute Maximum Ratings” table lists the maximum limits to which the device can be sub-
jected without damage.
This doesn´t imply that the device will function at these extreme con-
ditions,
only that, when these conditions are removed and the device operated within the
“Recommended Operating Conditions”, it will still be functional and its useful life won’t have been
shortened.
Parameter
Limit values
Unit
Remark
min.
typ.
max.
Ambient temperature, T
AOP
– 30
+70
°C
Storage temperature, T
AST
– 40
+85
°C
Voltage supply on +BAT
6
36
V
Reverse polarity protected
with 1A fuse.
Voltage on any pin with
respect to -BAT
36
V
Environmental ratings
Parameter
Remark
EMC
ISO 7637-2:2004, conducted emission
ISO 13766:2006/ISO 14982:1998, radiated emission
ISO 11452-4:2005, conducted susceptability
ISO 11452-2:2004, radiated susceptability
ISO 7637-2:2004, conducted transients susceptability
75/-100 V@12V, 150/-450 V@24 V
20-80 MHz, 1 kHz, 80% AM, 60 mA
80-2000 MHz, 1 kHz, 80% AM, 30 V/m
Pulse 1, 2a, 2b, 3a, 3b, 4, 5a, Level 3
ESD
ISO 10605:2008, operation
ISO 10605:2008, handling
15 kV, air
8 kV contact
8 kV contact
Mechanical environment
EN 60068-2-64:2008 Fh, randomvibration
EN 60068-2-27:2008 Ea, shock
EN 60068-2-29:1987 Eb, bump
15-1000 Hz, 11.6 g, 3x10 hours
30g, 11 ms, 3 in each axis/direction
15g, 11 ms, 500 in each axis/direction
Climate environment
EN 60529:2001, enclosure protection
EN 60068-2-30:2005 Db, damp heat cyclic
EN 60068-2-78:2001 Cab, damp heat steady state
EN60068-2-2:2007 Bb, heat operation
EN60068-2-2:2007 Bb, heat storage
EN 60068-2-1:1993-02 Ab, cold
EN 60068-2-14:1984 Nb, temperature cycle
IP54
+55°C, 95% RH, 6 cycles
+40°C, 93% RH, 21 days
+70°C, 72 hours
+85°C, 72 hours
-30°C, 16 hours
-30°C to +70°C, 100 cycles, 4 hours