4.5. Troubleshooting
We provide hereunder a symptom list in regard with their possible cause. This is not an
exhaustive list so in case of trouble, please refer to the associated inverter manual (the
diagnostic board indications will help you investigating) or contact us at:
http://www.parker.com/eme/repairservice
You note that the
motor does not turn by
hand when the motor
is not connected to the
drive.
Check if the phases are not in short circuit.
Check if the rotor is externally blocked mechanically in
rotation.
You have difficulty
starting the motor or
making it run
If there is a thermal protector, check it and its connection
and how it is set in the drive.
Check the servomotor insulation (in doubt, measure when
the motor is hot and cold.
The minimum insulation resistance measured under 500VDC
max
is 50 MΩ :
-
Between phase wire and housing,
-
Between thermal protector and housing,
-
Between resolver winding and housing.
You find that the motor
speed is drifting
Adjust the inverter offset.
You notice that the
motor is racing
Check the speed set-point of the inverter.
Check you are well and truly in speed regulation (and not
in torque regulation).
Check the (feedback device) setting
You notice vibrations
Check the (feedback device) connections, the earth
connections (carefully) and the earthing of the earth wire,
the setting of the inverter.
Check the stability of the secondary voltages.
Check the rigidity of the frame and motor support.
Check motor fixing on its base.
Check the balancing.
Check the alignment between motor and load.
You find that the motor
is too noisy
Several possible explanations :
-
Unsatisfactory mechanical balancing,
-
Defective coupling,
-
Loosening of several pieces,
-
Poor adjustment of the inverter of the position loop:
check rotation with the loop open.
-
Low drive switching frequency.
Summary of Contents for GVM Series
Page 2: ...2 18 06 08 PVD3668_GB_GVM_June_2018...
Page 16: ...16 18 06 08 PVD3668_GB_GVM_June_2018 Consult us for more demanding applications...
Page 33: ...33 18 06 08 PVD3668_GB_GVM_June_2018 GVM210 150 in Generator operation mode...
Page 39: ...39 18 06 08 PVD3668_GB_GVM_June_2018 3 3 Dimension drawings 3 3 1 GVM142 outline drawings...
Page 40: ...40 18 06 08 PVD3668_GB_GVM_June_2018...
Page 41: ...41 18 06 08 PVD3668_GB_GVM_June_2018...
Page 42: ...42 18 06 08 PVD3668_GB_GVM_June_2018 3 3 2 GVM210 outline drawings...
Page 43: ...43 18 06 08 PVD3668_GB_GVM_June_2018...
Page 44: ...44 18 06 08 PVD3668_GB_GVM_June_2018...
Page 45: ...45 18 06 08 PVD3668_GB_GVM_June_2018...
Page 46: ...46 18 06 08 PVD3668_GB_GVM_June_2018...
Page 47: ...47 18 06 08 PVD3668_GB_GVM_June_2018...
Page 53: ...53 18 06 08 PVD3668_GB_GVM_June_2018...
Page 55: ...55 18 06 08 PVD3668_GB_GVM_June_2018...
Page 60: ...60 18 06 08 PVD3668_GB_GVM_June_2018 With Oil with a 46 cSt viscosity 40 C input at 65 C...