8
Parker Hannifin Corporation
Proportional DC Valves
Series D*FC, D*1FC
Operation Manual
D_FC 5715-686 UK 07.02.2019
Technical Data
General
Design
Proportional directional control valve,
direct operated (D*FC), pilot operated (D*1FC)
Actuation
Proportional solenoid
Size
D*FC
D*1FC
NG06 (CETOP 03) / NG10 (CETOP 05)
NG10 (CETOP 05) / NG16 (CETOP 07) / NG25 (CETOP 08) /
NG32 (CETOP10)
Mounting interface
DIN 24340/ISO 4401/CETOP RP121/NFPA
Mounting position
unrestricted
Hysteresis
[%] <0.1
Ambient temperature
[°C] -20...+60
MTTF
D
value
1)
[years] D*FC: 150, D*1FC: 75
Weight
[kg] D*FC NG06 = 3.4 / NG10 = 7.7
D*1FC: NG10 = 9.0 / NG16 = 12.5 / NG25 = 21.0 / NG32 = 68.5
Vibration strength
[G] 10 Sinus 5...2000 Hz acc. IEC 60068-2-6
10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-36
15 Shock acc. IEC 60068-2-27
Hydraulic
Operating pressure
[bar] D*FC: Ports P, A, B 350, port T max. 35; 210 (external drain);
port Y max. 35
D*1FC: pilot oil internal P, A, B, X 350; T, Y 210
pilot oil external P, A, B, T, X 350; Y 210
Fluid
Hydraulic oil according to DIN 51524 ... 535, other on request
Fluid temperature
[°C] -20...+60 (NBR: -25...+60)
Viscosity permitted
recommended
[cSt]/[mm2/s]
[cSt]/[mm2/s]
20…400
30...80
Filtration
ISO 4406; 18/16/13
Electrical
Duty ratio
[%] 100
Protection class
IP65 acc. EN 60529 (with correctly mounted plug-in connector)
Supply voltage Us
[VDC] 18...30, electric shut-off at < 17, ripple < 5 % eff., surge free
Current consumption max.
[A] 2.0 (D1FC, D*1FC), 3.5 (D3FC)
Pre-fusing
[A] 2.5 (D1FC, D*1FC), 4.0 (D3FC)
Command signal
Uc
options
Ic
[V]
[mA]
[mA]
Codes B, K: +10...0...-10, ripple < 0.01 % eff., surge free,
Ri = 100 kOhm
Code S: 4...12...20, ripple < 0.01 % eff., surge free,
Ri = <250 Ohm
< 3.6 mA = enable off
> 3.8 mA = enable on (acc. NAMUR NE43)
Code E: +20...0...-20, ripple < 0.01 % eff., surge free, Ri = <250 Ohm
Differential input voltage
max.
[V]
[V]
[V]
[V]
Code 0/7: 30 for terminal D and E against PE (terminal G)
11 for terminal D and E against 0 V (terminal B)
Code 5: 30 for terminal 4 and 5 against PE (terminal
W
)
11 for terminal 4 and 5 against 0 V (terminal 2)
Adjustment ranges Min
[%] 0...50
Max
[%] 50...100
Ramp
[s] 0...32.5
Interface
RS232C, parametrizing connection 5pole
Enable signal (code 1/5/7)
[V] 5...30
Diagnostic signal
[V] +10...0...-10 / +12.5 error detection, rated max. 5 mA
EMC
EN 61000-6-2, EN 61000-6-4
Central connection
Code 0//7: 6+PE acc. EN 175201-804
Code 5: 11+PE acc. EN 175201-804
Cable specification
[mm²]
[mm²]
Code 0/7: 7 x 1.0 (AWG16) overall braid shield
Code 5: 8 x 1.0 (AWG20) overall braid shield
Cable length max.
[m] 50
1)
If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the
valve electronics voltage supply is to be switched off by a suitable switching element with sufficient reliability.
With electrical connections the protective conductor (PE
W
) must be connected according to the relevant regulations.
Summary of Contents for D 1FC Series
Page 26: ......