Parker D 1FC Series Operation Manual Download Page 8

8

Parker Hannifin Corporation

Proportional DC Valves

Series D*FC, D*1FC

Operation Manual

D_FC 5715-686 UK  07.02.2019

Technical Data

General

Design

Proportional directional control valve, 
direct operated (D*FC), pilot operated (D*1FC)

Actuation

Proportional solenoid

Size  

D*FC

  D*1FC

NG06 (CETOP 03) / NG10 (CETOP 05) 
NG10 (CETOP 05) / NG16 (CETOP 07) / NG25 (CETOP 08) /  
NG32 (CETOP10)

Mounting interface

DIN 24340/ISO 4401/CETOP RP121/NFPA

Mounting position

unrestricted

Hysteresis 

[%] <0.1

Ambient temperature

[°C] -20...+60

MTTF

D

 value 

1)

[years] D*FC: 150, D*1FC: 75

Weight

[kg] D*FC NG06 = 3.4 / NG10 = 7.7

D*1FC: NG10 = 9.0 / NG16 = 12.5 / NG25 = 21.0 / NG32 = 68.5

Vibration strength

[G] 10 Sinus 5...2000 Hz acc. IEC 60068-2-6

10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-36
15 Shock acc. IEC 60068-2-27

Hydraulic

Operating pressure

[bar] D*FC: Ports P, A, B 350, port T max. 35; 210 (external drain); 

port Y max. 35
D*1FC: pilot oil internal P, A, B, X 350; T, Y 210
pilot oil external P, A, B, T, X 350; Y 210

Fluid

Hydraulic oil according to DIN 51524 ... 535, other on request

Fluid temperature

[°C] -20...+60 (NBR: -25...+60)

Viscosity     permitted
 recommended 

[cSt]/[mm2/s]
[cSt]/[mm2/s]

20…400
30...80

Filtration

ISO 4406; 18/16/13

Electrical

Duty ratio

[%] 100

Protection class

IP65 acc. EN 60529 (with correctly mounted plug-in connector)

Supply voltage Us

[VDC] 18...30, electric shut-off at < 17, ripple < 5 % eff., surge free

Current consumption max.

[A] 2.0 (D1FC, D*1FC), 3.5 (D3FC)

Pre-fusing

[A] 2.5 (D1FC, D*1FC), 4.0 (D3FC)

Command signal  

Uc 

options 
 Ic

[V] 

[mA]

[mA]

Codes B, K: +10...0...-10, ripple < 0.01 % eff., surge free,  
Ri = 100 kOhm
Code S: 4...12...20, ripple < 0.01 % eff., surge free,  
Ri = <250 Ohm
< 3.6 mA = enable off
> 3.8 mA = enable on (acc. NAMUR NE43)
Code E: +20...0...-20, ripple < 0.01 % eff., surge free, Ri = <250 Ohm

Differential input voltage 
max.

[V] 
[V]
[V] 
[V]

Code 0/7: 30 for terminal D and E against PE (terminal G) 
11 for terminal D and E against 0 V (terminal B)
Code 5: 30 for terminal 4 and 5 against PE (terminal 

W

11 for terminal 4 and 5 against 0 V (terminal 2)

Adjustment ranges   Min

[%] 0...50

 Max

[%] 50...100

 Ramp

[s] 0...32.5

Interface

RS232C, parametrizing connection 5pole

Enable signal (code 1/5/7)

[V]  5...30

Diagnostic signal

[V] +10...0...-10 / +12.5 error detection, rated max. 5 mA

EMC

EN 61000-6-2, EN 61000-6-4

Central connection

Code 0//7:  6+PE acc. EN 175201-804
Code 5:  11+PE acc. EN 175201-804

Cable specification

[mm²]
[mm²]

Code 0/7: 7 x 1.0 (AWG16) overall braid shield
Code 5: 8 x 1.0 (AWG20) overall braid shield

Cable length max.

[m] 50

1)

   If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the 

valve electronics voltage supply is to be switched off by a suitable switching element with sufficient reliability.

With electrical connections the protective conductor (PE 

W

) must be connected according to the relevant regulations.

Summary of Contents for D 1FC Series

Page 1: ...ign 10 D 1FC Design 10 Parker Hannifin Manufacturing Germany GmbH Co KG Industrial Systems Division Europe Gutenbergstr 38 41564 Kaarst Germany Tel 49 181 99 44 43 0 E mail valvesisde parker com Copyr...

Page 2: ...system and components and assuring that all performance endurance maintenance safety and warning requirements of the application are met The user must analyze all aspects of the application follow ap...

Page 3: ...n on warranty and liability 10 CE mark 10 Personnel requirements 10 Compliance with other rules and instructions 10 2 Safety 10 Safety instructions 10 Use of the product 11 Limits of use 11 Contaminat...

Page 4: ...ed 4 Code Nominal size 1 NG06 CETOP 03 3 NG10 CETOP 05 Code Seal N NBR V FPM Code Signal Function B 0 10 V 0 10 V P A E 0 20 mA 0 20 mA P A K 0 10 V 0 10 V P B S 4 20 mA 12 20 mA P A Code Spool positi...

Page 5: ...ed electronics with position feedback Electrical options 2 Flow see catalogue Pilot connection see catalogue Code Nominal size 3 NG10 CETOP 05 4 NG16 CETOP 07 9 1 NG25 CETOP 08 11 NG32 CETOP 10 Code V...

Page 6: ...cations Characteristics of valve driver The described integral electronic driver combines all necessary functions for the optimal operation of the valve The most important features are digital circuit...

Page 7: ...DC Valves Series D FC D 1FC Operation Manual D_FC 5715 686 UK 07 02 2019 Block diagram of integral electronics D FC Code 0 6 PE D FC Code 5 11 PE D 1FC Code 0 6 PE D 1FC Code 5 11 PE D FC Code 7 6 PE...

Page 8: ...DC 18 30 electric shut off at 17 ripple 5 eff surge free Current consumption max A 2 0 D1FC D 1FC 3 5 D3FC Pre fusing A 2 5 D1FC D 1FC 4 0 D3FC Command signal Uc options Ic V mA mA Codes B K 10 0 10 r...

Page 9: ...715 686 UK 07 02 2019 Signal flow diagram Command Command E17 Option E19 Break P1 Zero Ramps S5 A S6 A S7 B S8 B Min Max P7 Min A P8 Min B P3 Max A P4 Max B PID Dither P5 Ampl P6 Freq PI Basic Mode Ex...

Page 10: ...f suspicion for a defect please return it to Parker CE mark The CE mark appears on the main nameplate If the product is installed as part of a larger machine this larger machine is in turn subject to...

Page 11: ...oil can cause allergic reactions on susceptible skin This can be prevented by taking the precautions that are usual when handling min eral oil products and by using personal protective equipment Leaki...

Page 12: ...ered with adequate corrosion protection provided our recommendations for the ambient conditions are followed Storage outside or in maritime or tropical climateswithoutappropriatepackagingleads to corr...

Page 13: ...ithout restrictions For operation with the following pressure fluids please consult Parker For detailed information concerning pressure fluids noteVDMA document 24317 as well as DIN 51524 51502 Specia...

Page 14: ...earth ground wire from the valve connecting cable as well as the cable shield have to be tied to the protective earth termi nal within the control unit It is necessary to usealowohmicpotentialconnecti...

Page 15: ...eed the max value of 30 V Non observance of this rule may result in perma nent damaging of the valve The increased inrush current of the valve should be considered when selecting the power supply A st...

Page 16: ...put will be clamped In case of restarting the enable signal the valve spool takes its position always out of the power down Preferable the enable signal should beswitchedontogetherwiththehydraulicpres...

Page 17: ...n follows the NAMUR specification NE43 NAMUR is an association of users of process control technology Command signal input Thecommandsignalforthevalvewillbeconnected to the pins D and E of the differe...

Page 18: ...al D_FC 5715 686 UK 07 02 2019 Wiring diagram of voltage command input 10 0 10 V Code 0 7 6 PE Wiring diagram of current command input 4 12 20 mA Code 0 7 6 PE Wiring diagram of voltage command input...

Page 19: ...this limit leads to malfunction up to destruction Diagnostics output A diagnostics signal is available Its voltage repre sents the operating condition of the valve The following information is availab...

Page 20: ...0 x 600 connection cable between PC and electronic module storage requirement approx 40 MB If your PC has no serial interface according to RS232 standard you require in addition an USB RS232 adapter f...

Page 21: ...ton Update list Parameters have to be nonvolatile stored on the valve via the button save parameter Thechosenparametersmaybeoptionallystored on the PC via the File menu with the menu item Save as data...

Page 22: ...al span for positive output signal To match the command signal span to the valve operating range 50 0 100 0 depending on valve P4 MAX B Adjustment of maximum signal span for negative output signal To...

Page 23: ...ating duration a change of the hydraulic fluid is required The frequency of change depends from the following circumstances kind resp grade of the pressure fluid filtering operating temperature and en...

Page 24: ...e X X X hydraulic fluid too viscous too cold change fluid grade provide operational temperature X X X too low oil level within tank refill pressure fluid X X X filter contaminated clean resp replace f...

Page 25: ...711 D111FC Bolt kit ordering code BK386 Code 0 1 3 7 female conn 6 PE ord code 5004072 Code 5 female conn 11 PE ord code 5004711 Hotline in Europe Phone 00800 2727 5374 Please direct technical product...

Page 26: ......

Reviews: