Parker D 1FC Series Operation Manual Download Page 21

21

Parker Hannifin Corporation

Proportional DC Valves

Series D*FC, D*1FC

Operation Manual

D_FC 5715-686 UK  07.02.2019

Program installation 

Please check before installation if the above hard-
ware requirements are met. If your PC has already 
stored an older version of the “ProPxD” program, 
it has to be deinstalled by using the Windows

®

 

system control feature.
Program installation sequence:
•  terminate the execution of other programs
•  execute the file “setup.exe”
•  follow the instructions on the screen
Answer the question, if an older version should be 
overwritten, with “ok”. During the installation you 
may change destination drive resp. installation path, 
if needed. Please answer “ok” if at the end of the 
installation the program reports any system informa-
tion. After successful installation the desktop display 
shows the ProPxD icon for starting the program.

Software operating

Brief instruction for first startup:
•  Connect the valve electronic to the supply voltage.
•  Connect the valve electronic to a PC via the 

parametrizing cable.

•  Start the operating program.
•  After displaying the program resp. data base ver-

sion a program window opens and the connected 
valve will be automatically identified (possibly a 
manual identification via the button “Receive all” 
is necessary).

•  Select the desired version via the menu “Op-

tions/Optionen” with the menu item “Language/
Sprache”. 

•  The valve specific default parameters are already 

available within the parameter table.

•  Individual parameters may be selected via 

mouse or the arrow buttons at the center of the 
program screen.

•  Parameter changes are possible via mouse or 

the arrow buttons on the bottom left within the 
program screen, also the parameter values may 
be edited via the keyboard.

•  Modified parameters will be stored via the “Enter” 

key or via the button “Update list”.

•  Parameters have to be nonvolatile stored on the 

valve via the button "save parameter".

•  The chosen parameters may be optionally stored 

on the PC via the “File”-menu with the menu item 
“Save as”, data retrieving is always possible via 
the function “Load file”

Extended functions

The user software is shared into 2 parameter ranges:
•  basic mode
•  expert mode
For normal startup the basic mode is absolutely 
sufficient. It permits the setting of all application 
specific parameters to match the valve function with 
the task setting. In case of special applications the 
valve parameters may be adapted via the expert 
mode. The operating mode may be selected from 
the “Options”- menu and remains after terminating 
and re-start of the program.

Changing of expert parameters is only permit-

ted for qualified personnel. Incorrect settings 
may lead to malfunction! In case of param-
eter changes shut the drive down!

The expert mode is protected by a pass word 
request. The name is “parker”. The button “Send 
parameter” appears in the “Expert”-operating mode. 
This button transmits only the setting of one single 
parameter to the connected valve. Thus a quick 
tuning of single parameters is permitted during 
the setup.

A horizontal bar graph readout between the 

communication buttons shows the data trans-
fer state. 

Because the ProPxD program has also offline 

(i.e. without connection to the valve) function-
ality, a manual pre-selection of the parameters 
is possible. After selection of the valve type 
via the menu “Options” the parameters may 
be set and stored for later transmission. Note 
the design series while selection of the valve!

The “File” menu provides the functions “Printer 
setup”, “Print preview” and “Print”. The print preview 
includes the option for parameter set storage as 
text file (format.txt) prior to further processing. The 
“Options” menu provides also the selection of the 
RS232C interface port via the menu item “Port”. 
Via the menu item “Load file” previously stored 
parameter sets may be loaded.

Summary of Contents for D 1FC Series

Page 1: ...ign 10 D 1FC Design 10 Parker Hannifin Manufacturing Germany GmbH Co KG Industrial Systems Division Europe Gutenbergstr 38 41564 Kaarst Germany Tel 49 181 99 44 43 0 E mail valvesisde parker com Copyr...

Page 2: ...system and components and assuring that all performance endurance maintenance safety and warning requirements of the application are met The user must analyze all aspects of the application follow ap...

Page 3: ...n on warranty and liability 10 CE mark 10 Personnel requirements 10 Compliance with other rules and instructions 10 2 Safety 10 Safety instructions 10 Use of the product 11 Limits of use 11 Contaminat...

Page 4: ...ed 4 Code Nominal size 1 NG06 CETOP 03 3 NG10 CETOP 05 Code Seal N NBR V FPM Code Signal Function B 0 10 V 0 10 V P A E 0 20 mA 0 20 mA P A K 0 10 V 0 10 V P B S 4 20 mA 12 20 mA P A Code Spool positi...

Page 5: ...ed electronics with position feedback Electrical options 2 Flow see catalogue Pilot connection see catalogue Code Nominal size 3 NG10 CETOP 05 4 NG16 CETOP 07 9 1 NG25 CETOP 08 11 NG32 CETOP 10 Code V...

Page 6: ...cations Characteristics of valve driver The described integral electronic driver combines all necessary functions for the optimal operation of the valve The most important features are digital circuit...

Page 7: ...DC Valves Series D FC D 1FC Operation Manual D_FC 5715 686 UK 07 02 2019 Block diagram of integral electronics D FC Code 0 6 PE D FC Code 5 11 PE D 1FC Code 0 6 PE D 1FC Code 5 11 PE D FC Code 7 6 PE...

Page 8: ...DC 18 30 electric shut off at 17 ripple 5 eff surge free Current consumption max A 2 0 D1FC D 1FC 3 5 D3FC Pre fusing A 2 5 D1FC D 1FC 4 0 D3FC Command signal Uc options Ic V mA mA Codes B K 10 0 10 r...

Page 9: ...715 686 UK 07 02 2019 Signal flow diagram Command Command E17 Option E19 Break P1 Zero Ramps S5 A S6 A S7 B S8 B Min Max P7 Min A P8 Min B P3 Max A P4 Max B PID Dither P5 Ampl P6 Freq PI Basic Mode Ex...

Page 10: ...f suspicion for a defect please return it to Parker CE mark The CE mark appears on the main nameplate If the product is installed as part of a larger machine this larger machine is in turn subject to...

Page 11: ...oil can cause allergic reactions on susceptible skin This can be prevented by taking the precautions that are usual when handling min eral oil products and by using personal protective equipment Leaki...

Page 12: ...ered with adequate corrosion protection provided our recommendations for the ambient conditions are followed Storage outside or in maritime or tropical climateswithoutappropriatepackagingleads to corr...

Page 13: ...ithout restrictions For operation with the following pressure fluids please consult Parker For detailed information concerning pressure fluids noteVDMA document 24317 as well as DIN 51524 51502 Specia...

Page 14: ...earth ground wire from the valve connecting cable as well as the cable shield have to be tied to the protective earth termi nal within the control unit It is necessary to usealowohmicpotentialconnecti...

Page 15: ...eed the max value of 30 V Non observance of this rule may result in perma nent damaging of the valve The increased inrush current of the valve should be considered when selecting the power supply A st...

Page 16: ...put will be clamped In case of restarting the enable signal the valve spool takes its position always out of the power down Preferable the enable signal should beswitchedontogetherwiththehydraulicpres...

Page 17: ...n follows the NAMUR specification NE43 NAMUR is an association of users of process control technology Command signal input Thecommandsignalforthevalvewillbeconnected to the pins D and E of the differe...

Page 18: ...al D_FC 5715 686 UK 07 02 2019 Wiring diagram of voltage command input 10 0 10 V Code 0 7 6 PE Wiring diagram of current command input 4 12 20 mA Code 0 7 6 PE Wiring diagram of voltage command input...

Page 19: ...this limit leads to malfunction up to destruction Diagnostics output A diagnostics signal is available Its voltage repre sents the operating condition of the valve The following information is availab...

Page 20: ...0 x 600 connection cable between PC and electronic module storage requirement approx 40 MB If your PC has no serial interface according to RS232 standard you require in addition an USB RS232 adapter f...

Page 21: ...ton Update list Parameters have to be nonvolatile stored on the valve via the button save parameter Thechosenparametersmaybeoptionallystored on the PC via the File menu with the menu item Save as data...

Page 22: ...al span for positive output signal To match the command signal span to the valve operating range 50 0 100 0 depending on valve P4 MAX B Adjustment of maximum signal span for negative output signal To...

Page 23: ...ating duration a change of the hydraulic fluid is required The frequency of change depends from the following circumstances kind resp grade of the pressure fluid filtering operating temperature and en...

Page 24: ...e X X X hydraulic fluid too viscous too cold change fluid grade provide operational temperature X X X too low oil level within tank refill pressure fluid X X X filter contaminated clean resp replace f...

Page 25: ...711 D111FC Bolt kit ordering code BK386 Code 0 1 3 7 female conn 6 PE ord code 5004072 Code 5 female conn 11 PE ord code 5004711 Hotline in Europe Phone 00800 2727 5374 Please direct technical product...

Page 26: ......

Reviews: