![Parker CW Series Service Instructions Manual Download Page 10](http://html1.mh-extra.com/html/parker/cw-series/cw-series_service-instructions-manual_4396692010.webp)
!
CAUTION:
Foot operated valves must be protected against inadvertent
operation that can cause serious bodily injury. Use of a pedal
guard (PS2043P) is strongly recommended, as it will reduce
the likelihood of inadvertent operation. If this is not suitable in
your application, utilize equivalent protection.
Valve Operation:
These valves will operate mounted in any position.
Valves can be operated either Normally Closed to pressure or Normally
Open to pressure.
In the normal position of the stem (spring returned), Port “A” is
blocked and Port “O” is connected to Port “B”. When actuated by the
foot, Port “A” is connected to Port “O” and Port “B” is blocked. When
the non-locking foot pedal is released, the spring returns the stem to
its normal position. In the locking model, the operator must release
the locking pedal to return the stem to its original (normal) position.
Connect inlet to Port “A” for normally closed valve. Port “B” is exhaust.
Connect inlet to Port “B” for normally open valve. Port “A” is exhaust.
Plug exhaust port for 2-way operation.
Port Identifications / Connections
A
B
C7 Locking
Normally Closed
C7 Locking
Normally Open
➤
A
B
➤
➤
➤
➤
A
B
C6 Non-Locking
Normally Closed
C6 Non-Locking
Normally Open
A
B
➤
A
O
O
O
O
B
➤
➤
➤
➤
➤
Application Limits
These products are intended for use in general purpose
compressed air systems only.
Operating Pressure Range:
psig
Bar
kPa
Minimum
0
0
0
Maximum
150
10
1000
Operating Temperature Range:
0°F to 160°F (-18°C to 71°C)
Installation & Operating Instructions
Valve should be installed with reasonable accessibility for service
whenever possible - repair service kits are available. Keep pipe or
tubing lengths to a minimum with inside clean and free of dirt and
chips. Pipe joint compound should be used sparingly and applied only
to the male pipe - never into the female port. Do not use PTFE tape to
seal pipe joints - pieces have a tendency to break off and lodge inside
the unit, possibly causing malfunction.
Filtered and lubricated air is necessary for maximum valve life and
minimum maintenance.
Factory Pre-Lubrication - All valves are pre-lubricated at assembly
with a petroleum based grease.
!
CAUTION:
This valve shall
NOT
be used to actuate a punch press. Do
NOT
use this valve on punch presses or press brakes. See OSHA
1910.217.
Installation & Service Instructions
V-227D
C6 & C7 Series Valves
ISSUED: September, 2000
Supersedes: February, 1994
ECN# P27805
Pneumatic Division North America
Richland, Michigan 49083
!
!
WARNING
To avoid unpredictable system behavior that can cause personal injury
and property damage:
• Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.
• Disconnect air supply and depressurize all air lines connected to
this product before installation, servicing, or conversion.
• Operate within the manufacturer’s specified pressure, temperature,
and other conditions listed in these instructions.
• Medium must be moisture-free if ambient temperature is below
freezing.
• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
• After installation, servicing, or conversion, air and electrical supplies
(when necessary) should be connected and the product tested for
proper function and leakage. If audible leakage is present, or the
product does not operate properly, do not put into use.
• Warnings and specifications on the product should not be covered
by paint, etc. If masking is not possible, contact your local
representative for replacement labels.
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF
THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR
RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND
PROPERTY DAMAGE.
This document and other infor mation from Par ker Hannifin
Corporation, its subsidiaries and authorized distributors provide
product and/or system options for further investigation by users
having technical expertise. It is impor tant that you analyze all
aspects of your application, including consequences of any failure
and review the information concerning the product or systems in
the current product catalog. Due to the variety of operating
conditions and applications for these products or systems, the
user, through its own analysis and testing, is solely responsible for
making the final selection of the products and systems and assuring
that all performance, safety and warning requirements of the
application are met.
The products described herein, including without limitation, product
features, specifications, designs, availability and pricing, are subject
to change by Parker Hannifin Corporation and its subsidiaries at
any time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR
INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE
THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.