CAUTION:

Foot operated valves must be protected against inadvertent
operation that can cause serious bodily injury. Use of a pedal
guard (PS2043P) is strongly recommended, as it will reduce
the likelihood of inadvertent operation. If this is not suitable in
your application, utilize equivalent protection.

Valve Operation:

These valves will operate mounted in any position.

Valves can be operated either Normally Closed to pressure or Normally
Open to pressure.

In the normal position of the stem (spring returned), Port “A” is
blocked and Port “O” is connected to Port “B”. When actuated by the
foot, Port “A” is connected to Port “O” and Port “B” is blocked. When
the non-locking foot pedal is released, the spring returns the stem to
its normal position. In the locking model, the operator must release
the locking pedal to return the stem to its original (normal) position.

Connect inlet to Port “A” for normally closed valve. Port “B” is exhaust.

Connect inlet to Port “B” for normally open valve. Port “A” is exhaust.

Plug exhaust port for 2-way operation.

Port Identifications / Connections

A

B

C7 Locking

Normally Closed

C7 Locking

Normally Open

A

B

A

B

C6 Non-Locking

Normally Closed

C6 Non-Locking

Normally Open

A

B

A

O

O

O

O

B

Application Limits

These products are intended for use in general purpose
compressed air systems only.

Operating Pressure Range:

psig

Bar

kPa

Minimum

0

0

0

Maximum

150

10

1000

Operating Temperature  Range:

0°F to 160°F (-18°C to 71°C)

Installation & Operating Instructions

Valve should be installed with reasonable accessibility for service
whenever possible - repair service kits are available. Keep pipe or
tubing lengths to a minimum with inside clean and free of dirt and
chips. Pipe joint compound should be used sparingly and applied only
to the male pipe - never into the female port. Do not use PTFE tape to
seal pipe joints - pieces have a tendency to break off and lodge inside
the unit, possibly causing malfunction.

Filtered and lubricated air is necessary for maximum valve life and
minimum maintenance.

Factory Pre-Lubrication - All valves are pre-lubricated at assembly
with a petroleum based grease.

!

CAUTION:

This valve shall 

NOT

 be used to actuate a punch press. Do 

NOT

use this valve on punch presses or press brakes. See OSHA
1910.217.

Installation & Service Instructions
V-227D

C6 & C7 Series Valves

ISSUED:  September, 2000
Supersedes:  February, 1994

ECN# P27805

Pneumatic Division North America
Richland, Michigan 49083

!

!

 

WARNING

To avoid unpredictable system behavior that can cause personal injury
and property damage:

• Disconnect electrical supply (when necessary) before installation,

servicing, or conversion.

• Disconnect air supply and depressurize all air lines connected to

this product before installation, servicing, or conversion.

• Operate within the manufacturer’s specified pressure, temperature,

and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is below

freezing.

• Service according to procedures listed in these instructions.

• Installation, service, and conversion of these products must be

performed by knowledgeable personnel who understand how
pneumatic products are to be applied.

• After installation, servicing, or conversion, air and electrical supplies

(when necessary) should be connected and the product tested for
proper function and leakage. If audible leakage is present, or the
product does not operate properly, do not put into use.

• Warnings and specifications on the product should not be covered

by paint, etc. If masking is not possible, contact your local
representative for replacement labels.

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF
THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR
RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND
PROPERTY DAMAGE.
This document and other infor mation from Par ker Hannifin
Corporation, its subsidiaries and authorized distributors provide
product and/or system options for further investigation by users
having technical expertise. It is impor tant that you analyze all
aspects of your application, including consequences of any failure
and review the information concerning the product or systems in
the current product catalog. Due to the variety of operating
conditions and applications for these products or systems, the
user, through its own analysis and testing, is solely responsible for
making the final selection of the products and systems and assuring
that all performance, safety and warning requirements of the
application are met.
The products described herein, including without limitation, product
features, specifications, designs, availability and pricing, are subject
to change by Parker Hannifin Corporation and its subsidiaries at
any time without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR
INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE
THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

Summary of Contents for CW Series

Page 1: ...2 CW12 Valves Installation Service Instructions C6 C7 Valves Installation Service Instructions CS1 CWS1 Valves Installation Service Instructions Flow Control for CC Valves Installation Service Instruc...

Page 2: ...ent for the two power leads Note Follow all requirements for local and national electrical codes Valve Operation These valves will operate mounted in any position they are also suitable for vacuum ser...

Page 3: ...PL2481 CWJ137 3 8 NPTF Ports PL2482 Solenoid Identification and Specifications Solenoid Assembly 60 Hz AC 50Hz AC P6972801 120 P6972802 240 P6972806 24 P6972815 110 P6972824 220 When CJ1 or CWJ1 valve...

Page 4: ...CW94 Series Valves ISSUED November 2009 Supersedes September 2000 Doc V222D EN 090938 Rev 5 Pneumatic Division Richland Michigan 49083 269 629 5000 WARNING To avoid unpredictable system behavior that...

Page 5: ...L2481 CW37 3 8 NPTF Ports PL2482 Hand Toggle Actuator Assembly Non Locking PL3355 Locking PL2212 Cam Head Assembly Ball C CW2 PL2209 Roller C CW13 PL2422 Heavy Duty Roller Uni Directional C CW92 PL403...

Page 6: ...and Michigan 49083 WARNING To avoid unpredictable system behavior that can cause personal injury and property damage Disconnect electrical supply when necessary before installation servicing or conver...

Page 7: ...to service this unit contact your local authorized dealer or your customer service representative Maintenance Trouble Shooting Hints Air Leakage Through Exhaust Ports 1 Check for internal leakage in c...

Page 8: ...to be increased as line pressure is increased Series C CW wall mounting valves can be operated either Normally Closed to pressure or Normally Open to pressure A B O O A B Normally Closed Normally Ope...

Page 9: ...orts PL3268 End Plug 1 1 16 Hex P69919 Pressure Actuated Head Ass y PL3244 Part Identification List Item Description 1 Valve Body Assembly 2 Valve Body 3 Stem Retainer Snap Ring 4 Stem O ring 5 Stem 6...

Page 10: ...2000 Supersedes February 1994 ECN P27805 Pneumatic Division North America Richland Michigan 49083 WARNING To avoid unpredictable system behavior that can cause personal injury and property damage Disc...

Page 11: ...questions concerning how to service this unit contact your local authorized dealer or your customer service representative Maintenance Trouble Shooting Hints Air Leakage Through Exhaust Ports 1 Check...

Page 12: ...connected to this product before installation servicing or conversion Operate within the manufacturer s specified pressure temperature and other conditions listed in these instructions Medium must be...

Page 13: ...ssure then reaches head of work valve and work cylinder advances Return Stroke De energizing clamp valve exhausts head of clamping cylinder and Port 02 of CS1 CS1 returns to ACTUATED position exhausti...

Page 14: ...eparate flow control valves Air is exhausted through a single valve port requiring only one muffler or piped exhaust connection Adjusting screws with fine threads have metering tapers designed to give...

Page 15: ...ember 2003 Supersedes May 2003 Doc V 285EP ECN 030951 Rev 6 Pneumatic Division Richland Michigan 49083 WARNING To avoid unpredictable system behavior that can cause personal injury and property damage...

Page 16: ...unting screws from 1 7 to 2 0 Nm 15 to 18 in lb of torque If body is removed from base torque mounting screws to 11 3 to 14 1 Nm 100 125 in lb of torque when reassembling If you have questions concern...

Page 17: ...fore installation servicing or conversion Operate within the manufacturer s specified pressure temperature and other conditions listed in these instructions Medium must be moisture free if ambient tem...

Page 18: ...eals Item 3 Use a nondetergent hydro carbon base oil or grease 6 Insert new spool Item 1 and return spring Item 2 CC10 only from the service kit into the body Spring return end of valve is A 01 If val...

Page 19: ...nd the product tested for proper function and leakage If audible leakage is present or the product does not operate properly do not put into use Warnings and specifications on the product should not b...

Page 20: ...LURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH PERSONAL INJURY AND PROPERTY DAMAGE This document and other information from...

Page 21: ...ntenance safety and warning requirements are met and that the application presents no health or safety hazards Complying with all existing warning labels and or providing all appropriate health and sa...

Page 22: ...onents Air leakage Look and listen to see if there are any signs of visual damage to any of the components in the system Leakage is an indication of worn or damaged components Damaged or degraded comp...

Reviews: