Packaging, transport, storage 

2.4 

Packaging, transport, storage 

Packaging material and transport 

 

 

Caution! 

The packaging material is inflammable, if it is disposed of improperly by burning, 
lethal fumes may develop. 

The packaging material must be kept and reused in the case of a return shipment. 
Improper or faulty packaging may lead to transport damages. 
Make sure to transport the drive always in a safe manner and with the aid of 
suitable lifting equipment (

Weight

 (see on page 18)). Do never use the electric 

connections for lifting. Before the transport, a clean, level surface should be 
prepared to place the device on. The electric connections may not be damaged 
when placing the device. 

 

First device checkup 

 

Check the device for signs of transport damages.

 

Please verify, if the indications on the 

Type identification plate

 (see on page 5)

correspond to your requirements.

 

Check if the consignment is complete.

Disposal 

This product contains materials that fall under the special disposal regulation from 
2010, which corresponds to the EC directory 2008/98/EC for dangerous disposal 
material. We recommend to dispose of the respective materials in accordance with 
the respectively valid environmental laws. The following table states the materials 
suitable for recycling and the materials which have to be disposed of separately. 

 

Material 

suitable for 

recycling 

Disposal 

Metal 

yes 

no 

Plastic materials 

yes 

no 

Circuit boards 

no 

yes 

 

Please dispose of the circuit boards according to one of the following methods: 

 

Burning at high temperatures (at least 1200°C) in an incineration plant licensed in
accordance with part A or B of the environmental protection act.

 

Disposal via a technical waste dump which is allowed to take on electrolytic
aluminum condensers. Do under no circumstances dump the circuit boards at a
place near a normal waste dump.

Storage 

If you do not wish to mount and install the device immediately, make sure to store it 
in a dry and clean environment. Make sure that the device is not stored near strong 
heat sources and that no metal chippings can get into the device. 

 

 

Please note in the 

event of storage >1 

year: 

Forming the capacitors 

Forming the capacitors only required with 400 VAC axis controllers and 

mains module PSUP 

If the device was stored longer than one year, the intermediate capacitors must be 
re-formed! 

Forming sequence: 

 

Remove all electric connections

 

Supply the device with 230VAC single phase for 30 minutes

 

via the L1 and L2 terminals on the device or

 

with multi axis devices via L1 and L2 on the mains module PSUP.

192-

120148N13 2019-06

Summary of Contents for Compax3M Series

Page 1: ...ti axis devices 192 120148N13 2019 06 Release as from R09 63 192 120148N13 2019 06 We reserve the right to make technical changes The data correspond to the current status at the time of printing DOC...

Page 2: ...echanical Drives Division EME Robert Bosch Strasse 22 77656 Offenburg Germany Tel 49 0781 509 0 Fax 49 0781 509 98176 Internet www parker com eme http www parker com eme E mail sales automation parker...

Page 3: ...online help files Please note that the help files are associated with defined device and software versions Status of the Manuals Help and PDFs are updated simultaneously In case of doubt the HTML help...

Page 4: ...ts Supplied 3 1 1 C3 ServoManager 3 2 Introduction 5 2 1 Device assignment 5 2 2 Scope of delivery 5 2 3 Type specification plate 5 2 4 Packaging transport storage 7 2 5 Safety instructions 8 2 5 1 Ge...

Page 5: ...s module PSUP20D6 mains module PSUP30D6 mains module 2 2 Scope of delivery Device accessories Device accessories for Compax3M Cable clamps in different sizes for large area shielding of the motor cabl...

Page 6: ...supply V2 Mains supply voltage 2 230VAC 240VAC 4 400VAC 480VAC 3 Unique number of the particular device 4 Nominal supply voltage Power Input Input supply data Power Output Output data 5 Designation o...

Page 7: ...environmental laws The following table states the materials suitable for recycling and the materials which have to be disposed of separately Material suitable for recycling Disposal Metal yes no Plas...

Page 8: ...rvices who have read and will observe the safety instructions who have read and observe the manual or help or the sections pertinent to the work to be carried out This applies to all work relating to...

Page 9: ...mounting methods Note on exchange of options Device options must be exchanged in the factory to ensure hardware and software compatibility When installing the device make sure the heat dissipators of...

Page 10: ...hed with the device The shield of the cable must also be connected with the motor housing The fixing via plug or screw in the terminal box depends on the motor type 80m Corresponding to the specificat...

Page 11: ...in the accessories chapter they feature a temperature rating of at least 60 C Maximum Surrounding Air Temperature 40 C Control voltage supply 24VDC only permissible with class 2 power supply Compax3M...

Page 12: ...the cables described in the accessories chapter they feature a temperature rating of at least 60 C Maximum Surrounding Air Temperature 40 C Control voltage supply 24VDC only permissible with class 2 p...

Page 13: ...on the following factors Length and properties of the motor cable Switching frequency Operation with or without external mains filter Motor cable with or without shield network Motor housing groundin...

Page 14: ...Introduction 2 8 EC declaration of conformity Compax3M 14 192 120148N13 2019 06 Multi axis devices...

Page 15: ...Parker EME EC declaration of conformity PSUP 2 9 EC declaration of conformity PSUP 192 120148N13 2019 06 15...

Page 16: ...screw type e g 5 9Nm for M5 screw DIN 912 8 8 Connection of the internal supply voltage The Compax3M axis controllers are connected to the supply voltages via the rail modules Details Deblocking the...

Page 17: ...to other temperature influences than that of the devices mounted on this very plate The devices must be mounted vertically on a level surface Make sure that all devices are sufficiently fixed 3 2 1 Mo...

Page 18: ...g and dimensions PSUP20 PSUP30 C3M300D6 Information on PSUP20 PSUP30 C3M300D6 Mounting 4 socket head screws M5 100mm 360mm 263mm 96mm 400mm 90 50 5mm 50 5mm 101mm Tolerances DIN ISO 2768 f 18 192 1201...

Page 19: ...mum fuse rating per device 2 special purpose fuses in line are required Cable protection measure MCB K characteristic with a rating of 50A 4xxVAC depending on the input voltage Recommendation ABB S203...

Page 20: ...Technical Data 20 192 120148N13 2019 06 Multi axis devices...