CM2904 Instruction Book © 2009 - 2022 Parker-Hannifin Corporation Page 26 of 51
CM2904 Standard software
Message definitions
Byte
Bit / Bits
Description
Type
Values
1
7
8
MDIN8
Measurement
11=Not available
2
1
2
MDIN9
Measurement
2
3
4
MDIN10
Measurement
2
5
6
MDIN11
Measurement
2
7
8
MDIN12
Measurement
3
1
2
MDIN13
Measurement
3
3
4
MDIN14
Measurement
3
5
6
MDIN15
Measurement
3
7
8
MDIN16
Measurement
4
1
2
MDIN17
Measurement
4
3
4
MDIN18
Measurement
4
5
6
MDIN19
Measurement
4
7
8
Not used
Measurement
5
1
:
8
Not used
Measurement
6
1
:
8
Not used
Measurement
7
1
:
8
Not used
Measurement
8
1
:
8
Not used
Measurement
6.3.2. ADC1
Transmission repetition rate:
- Forced update period=100ms,
- Otherwise update period = 20ms on signal changes