![Parker C3F001D2 F12 I11 T30 Installation Manual Download Page 8](http://html1.mh-extra.com/html/parker/c3f001d2-f12-i11-t30/c3f001d2-f12-i11-t30_installation-manual_755727008.webp)
Introduction
Hydraulics controller
8
192-121100 N6 June 2008
2.2
Type specification plate Compax3 Fluid
You will find the exact description of the device on the type specification
plate, which is located on the right side of the device:
Explanation:
1 Type
designation The complete order designation of the device (2, 6, -9...)
(Category No.)
2 C3F001D2
C3:
Abbreviation for Compax3
F =Fluid:
Hydraulics controller
001:
+/-10V and 0..20mA outputs (16 Bit)
D2:
24VDC device
3
Unique number of the particular device
4
Supply voltage
24 VDC
5
Date of factory test
6
Designation of the
feedback system
F12:
Feedback Module
7 Device
interface
I11 / I12:
Digital Inputs / Outputs and RS232 / RS485
I20:
Profibus DP
I21:
CANopen
I22:
DeviceNet
8 Technology
function
T11:
Positioning / pressure/force control
T30:
Motion control programmable according to IEC61131-3
T40:
Electronic cam generation
9 Options
Mxx:
10 CE
compliance
11 UL
certification
PD2
(see page 25)
(degree of pollution)
Type specification
plate Compax3
Fluid: