Parker EME
Specifications
192-121100 N6 June 2008
25
Supported valves and feedback systems
Valves
D1*FH series
Absolute encoder
Analog 0..20mA, 4..20mA, ±10V
Start/Stop - interface
SSI interface
EnDat 2.1-interface
1VSS (max. 400kHz) Interface, 13.5bits /
graduationof the scale
RS422 encoder (max. 5MHz), internal
quadrature of the resolution
EMC limit values
EMC interference emission
Limit values according to EN 61000-6-4: 2001
for the industrial environment
EMC disturbance immunity
Limit values according to EN 61000-6-2: 2001
for the industrial environment
Environmental requirements Compax3F
General ambient conditions
According to
EN 60 721-3-1 to 3-3
Climate (temperature/humidity/barometric
pressure): Class 3K3
Permissible ambient temperature:
Operation
Storage
Transport
0 to +45 C
Class 3K3
-25 to +70 C
Class 2K3
–25 to +70 C
Class 2K3
Tolerated humidity:
No condensation
Operation
Storage
Transport
<= 85% class 3K3
<= 95% class 2K3
<= 95% class 2K3
(Relative humidity)
Elevation of operating site
<=1000m above sea level for 100% load
ratings
<=2000m above sea level for 1% / 100m
power reduction
Please inquire for greater elevations
Mechanic resonances:
EN 60068-2-6 (sinusoidal excitation)
Sealing
IP20 protection class according to EN 60 529
Insulation requirements
Degree of contamination
Level of contamination 2 according to EN 50 178