Parker C3F001D2 F12 I11 T30 Installation Manual Download Page 1

 

 

Com

pax

Electromechanical Automation

We reserve the right to make technical changes. 

20.06.08 11:26 

192-121100 N6 June 2008 

The data correspond to the current status at the time of printing.   

Compax3 Fluid Installation Manual 

Hydraulics controller 

 

192-121100 N6 

June 2008 

Release R08-0 

C3Manager-Compax3F 

Unterlagen / Software 
user guides / tools 
manuels / tools: 

‹

 

Compax3 - DVD (english, deutsch, français) 
+  

‹

 

Compax3F Installations-Handbuch deutsch 

‹

 

Compax3F Installation Manual english 

Summary of Contents for C3F001D2 F12 I11 T30

Page 1: ...rrespond to the current status at the time of printing Compax3 Fluid Installation Manual Hydraulics controller 192 121100 N6 June 2008 Release R08 0 C3Manager Compax3F Unterlagen Software user guides...

Page 2: ...com Parker Hannifin GmbH Co KG registered office Bielefeld Amtsgericht Bielefeld HRA 14808 Personally liable shareholder Parker Hannifin Management GmbH Amtsgericht Bielefeld HRB 35489 executive board...

Page 3: ...voManager software tool is also functioning independently from the Parker Integrated Engineering Tool After the installation of the ServoManager you can copy the desired Online help system with the C3...

Page 4: ...Browser MS Internet Explorer 6 x Processor 1 5GHz RAM memory 512MB Hard disk 10GB available memory Drive DVD drive Monitor Resolution 1024x768 or higher Graphics card on onboard graphics for performa...

Page 5: ...nd make the setting for the selected interface in the menu Options Communication settings RS232 RS485 In the menu tree under device selection you can read the device type of the connected device Onlin...

Page 6: ...of delivery 13 3 2 Plug and connector assignment Compax3 Fluid 13 3 2 1 Meaning of the front panel LEDs via X10 13 3 2 2 Plug and connector assignment 14 3 2 3 Plug and connector assignment complete...

Page 7: ...rt storage 9 Safety Instructions 10 Warranty conditions 11 Conditions of utilization for CE conform operation 12 2 1 Device assignment Compax3 Fluid This manual applies to the following devices C3F001...

Page 8: ...controller 001 10V and 0 20mA outputs 16 Bit D2 24VDC device 3 Unique number of the particular device 4 Supply voltage 24 VDC 5 Date of factory test 6 Designation of the feedback system F12 Feedback M...

Page 9: ...and install the device immediately make sure to store it in a dry and clean environment Make sure that the device is not stored near strong heat sources and that no metal chippings can get into the d...

Page 10: ...his purpose 2 4 2 Safety conscious working This device may be operated only by qualified personnel Qualified personnel in the sense of these operating instructions consists of Persons who by virtue to...

Page 11: ...re that all axes are sufficiently fixed Attention during configuration downloads with master slave couplings electronic gear cam Deactivate the drive before starting the configuration download Master...

Page 12: ...eld of the valve cable must also be connected with the valve housing The fixing via plug or screw in the terminal box depends on the valve type 100m Use only with aligned controller to avoid control l...

Page 13: ...panel LEDs via X10 13 Plug and connector assignment 14 Plug and connector assignment complete 15 Analog Input plug X1 16 Analog Output plug X2 17 Voltage supply plug X3 18 RS232 RS485 interface plug X...

Page 14: ...100 N6 June 2008 3 2 2 Plug and connector assignment X13 X12 X11 X10 X3 X2 X1 LED1 X1 Analog Inputs X2 Analog Outputs X3 24 VDC power supply X10 RS232 RS485 X11 2 Feedback Type X12 Inputs Outputs X13...

Page 15: ...put24VDC O9 I9 O10 I10 O11 I11 InputGND X22 Input Output option M12 M10 HEDA HEDA motionbus option M11 M10 I Os X20 6 Lx X20 7 res X20 8 res X20 HEDA in X20 1 Rx X20 2 Rx X20 3 Lx X20 4 res X20 5 res...

Page 16: ...Supply Sensor 3 15 IN3 Signal Sensor 3 16 IN3 Signal Sensor 3 17 IN4 10V Input 4 18 IN4 10V Input 4 19 IN5 10V Input 5 20 IN5 10V Input 5 Requirement Connection cable Use shielded cables Shield conne...

Page 17: ...age 10V 1000 Current 4 20mA 600 Current 100mA 100 All outputs are short circuit proof Requirement Connection cable Use shielded cables Shield connection of the cables The cable should be fully screene...

Page 18: ...tage supply 24VDC Controller type Compax3 F001 D2 Voltage range 21 27VDC Mains module with switch on current limitation due to capacitive load Fuse MTP miniature circuit breaker or delayed action fuse...

Page 19: ...e Sub D Pin 1 and 9 jumpered externally 1 Enable RS485 5V 2 res 3 TxD_RxD 4 res 5 GND 6 res 7 TxD_RxD 8 res 9 5V RS485 4 wire PIN X10 RS485 four wire Sub D Pin 1 and 9 externally jumpered 1 Enable RS4...

Page 20: ...em X11 High Density Sub D PIN D A Monitor RS422 Encoder Start Stop Time of Flight SSI 1 24V max 100mA 24V max 100mA 2 3 Aout1 4 Aout0 5 5V for encoder max 150mA 6 A INIT Clock 7 A INIT Clock 8 B STSP...

Page 21: ...ice specific assignment in the online help which can be opened from the Compax3 ServoManager Maximum capacitive loading of the outputs 50nF max 4 Compax3 inputs 3 2 9 1 Connection of the digital Outpu...

Page 22: ...ncoder side Vcc 5V controlled on the encoder side Vcc 5V controlled on the encoder side 5 5V for encoder max 150mA 5V 5V 6 A Clock INIT Clock 7 A Clock INIT Clock 8 B COS COS STSP 9 SIN SIN 10 11 Sens...

Page 23: ...ing and dimensions Mounting 3 socket head screws M5 or by direct snapping on a 35mm supporting rail according to DIN EN 50 022 Mounting material DIN rail clip and distance piece available as accessori...

Page 24: ...Compax3 F001 D2 Dimensions HxWxD mm 199x80x130 Weight kg 2 0 Housing protection class Enclosed metal housing insulation according to EN60529 IP 20 Inputs and outputs Controller type Compax3 F001 D2 8...

Page 25: ...mental requirements Compax3F General ambient conditions According to EN 60 721 3 1 to 3 3 Climate temperature humidity barometric pressure Class 3K3 Permissible ambient temperature Operation Storage T...

Page 26: ...508 Listed CNL according to C22 2 No 142 M1987 Listed Certified E File_No E198563 The UL certification is documented by a UL logo on the device type specification plate UL logo Detailed information on...

Page 27: ...Parker EME Specifications 192 121100 N6 June 2008 27...

Page 28: ...of the front panel LEDs via X10 13 Mounting and dimensions 23 N Notes on the Documents Supplied 3 P Packaging transport storage 9 Plug and connector assignment 14 Plug and connector assignment Compax...