![Parker ADAPTOMODE A4AO Installation, Service And Parts Information Download Page 11](http://html1.mh-extra.com/html/parker/adaptomode-a4ao/adaptomode-a4ao_installation-service-and-parts-information_3869894011.webp)
Refrigerating Specialties Division
11
Repair Kits for A4AO, A4AOE, A4AOS and A4AOSE
32mm (1-1/4”)
40mm (1-5/8”)
50mm (2”)
65mm (2-1/2”)
75mm (3”)
100mm (4”)
Flange Bolt Package includes bolts and nuts; no gaskets (cont’d from page 9)
Item No.
Kit No.
Qty
Kit No.
Qty
Kit No.
Qty
Kit No.
Qty
Kit No.
Qty
Kit No.
Qty
50,52-54
200518
200518
200518
200518
200518
200518
52
Only Avail. with Kit 1
Only Avail. with Kit
1
Only Avail. with Kit
1
Only Avail. with Kit
1
Only Avail. with Kit 1
Only Avail. with Kit 1
54
Only Avail. with Kit 1
Only Avail. with Kit
1
Only Avail. with Kit
1
Only Avail. with Kit
1
Only Avail. with Kit 1
Only Avail. with Kit
1
50
Only Avail. with Kit
1
Only Avail. with Kit
1
Only Avail. with Kit
1
Only Avail. with Kit
1
Only Avail. with Kit
1
Only Avail. with Kit 1
FK-32
FK-40
FK-50
FK-65
FK-75
FK-100
FPT, SW,
FPT, SW,
FPT, SW,
FPT, SW,
FPT, SW,
FPT, SW,
WN
ODS
WN
ODS
WN
ODS
WN
ODS
WN
ODS
WN
ODS
Also
Also
Also
Also
Also
Also
Also
Also
Also
Also
Also
Also
Std Avail Std
Avail Std Avail Std
Avail
Std Avail Std Avail
Std Avail Std Avail Std Avail Std Avail Std Avail Std Avail
1¼ 1½ 13/8 15/8, 21/8 1½
2 15/8 21/8, 25/8 2
1½ 21/8 25/8 25/8
25/8 31/8
3
31/8 35/8
4
41/8
TABLE OF DIMENSIONS FOR INLET PRESSURE Types A4AO, A4AOE, A4AOS, A4AOSE
TYPE
20mm & 25mm
32mm
40mm & 50mm
65mm
75mm
100mm
(3/4 & 1 “)
(1-1/4”)
(1-5/8 & 2”)
(2-1/2”)
(3”)
(4”)
DIMENSIONS
mm inches
mm
inches
mm inches
mm
inches
mm
inches
mm
inches
A
454
17.9
472
18.6
525
20.7
538
21.2
657
25.9
710
28.4
B
148
5.8
162
6.3
177
6.9
181
7.1
273
10.7
292
11.5
C
177
6.7
216
8.5
264
10.4
264
10.4
324
12.7
352
14.6
D
1/2”
229
9.0
1-1/4” 269
10.6
(FPT) FOR
3/4”
229
9.0
1-1/2”
320
12.6
2-1/2” 344
13.5
3”
402
15.8
4”
463
18.2
PIPE SIZES
1”
229
9.0
1-1/2” 269
10.6
SHOWN
1-1/4” 229
9.0
E
1/2”
229
9.0
1-1/4” 269
10.6 1-1/2”
320
12.6
(S.W.)FOR
3/4”
229
9.0
2-1/2” 344
13.5
3”
402
15.8
4”
463
18.2
PIPE SIZES
1”
229
9.0
1-1/2” 269
10.6
2”
320
12.6
SHOWN
1-1/4” 229
9.0
F
(W.N.) FOR
3/4”
267
10.5
1-1/4” 313
12.3 1-1/2”
377
14.8
2-1/2” 414
16.1
3’
491
19.3
4”
584
23.0
PIPE SIZES
1”
274
10.8
1-1/2” 317
12.5
2”
384
15.1
SHOWN
1-1/4” 274
10.0
G
7/8”
252
9.9
2-5/8” 361
14.2
3-1/8” 427
16.8
(O.D.S.) FOR 1-1/8” 252
9.9
1-3/8” 282
11.1 1-5/8”
371
14.6
TUBE SIZES 1-3/8” 244
9.6
1-5/8” 292
11.5 2-1/8”
351
13.8
4-1/8”
516
20.3
SHOWN
1-5/8” 252
9.9
2-1/8” 318
12.5 2-5/8”
371
14.6
3-1/8” 402
15.8
3-5/8” 445
17.5
H
117
4.6
117
4.6
140
5.5
159
6.2
178
7.0
222
8.8
J
98
3.9
178
7.0
251
9.9
314
12.4
314
12.4
363
14.3
K
112
4.4
112
4.4
117
4.6
124
4.9
142
5.6
157
6.2
L
122
4.8
122
4.8
135
5.3
133
5.2
122
4.8
152
6.0
A4AO, A4AOE
A4AOS, A4AOSE
H
F
G
WELD NECK
FLANGE
ODS SOLDER
FLANGE
B
C
D
E
J
ADD FOR
STRAINER
SUBTRACT 13mm
1/2" FOR OE
(FPT FLANGES)
(SW FLANGES)
ALLOW 25mm (1")
BELOW VALVE TO OPERATE
MANUAL OPENING STEM
ALLOW 75mm (3") ABOVE VALVE
TO OPERATE ADJUSTING STEM
ALLOW 75mm (3") ABOVE VALVE
TO OPERATE ADJUSTING STEM
WELD NECK
FLANGE
ODS SOLDER
FLANGE
G
F
H
L
K
A
J
D
E
B
C
ADD FOR
STRAINER
(FPT FLANGES)
(SW FLANGES)
SUBTRACT 13mm
1/2" FOR OES
ALLOW 25mm (1")
BELOW VALVE TO OPERATE
MANUAL OPENING STEM