Easy Start Guide

3. Motor Connections - Star and Delta

Page 4

This guide has been produced by The Inverter Drive Supermarket Ltd.
All content, including but not limited to graphics, text and procedures copyright

The Inverter

Drive Supermarket and must not be reproduced or altered without prior written permission.

©

The order of the three phases determines the
direction the motor turns.

3.2 Motor connected in DELTA:

The link configuration is shown in the
illustration opposite and is sometimes referred
to as “three-a-breast”.

Note that the manufacturer recommends that
the cable screen is earthed at both ends and
the motor and Inverter are earthed separately.

3.1 Motor connected in STAR (or Wye):

The order of the three phases determines the
direction the motor turns.

Only two links are required for Star. Double-up
the links if changing from Delta to allow the
motor to be changed back in future.

For safety purposes, Star (shown opposite) is
the default configuration for small motors
(usually to 3kW) and is sometimes known as
“two at one side”.

Note that the manufacturer recommends that
the cable screen is earthed at both ends and
the motor and Inverter are earthed separately.

The two ways of connecting the links

are

shown below. These are known as “Star” (the
higher voltage) or “Delta” (the lower voltage).

Dual voltage induction motors typically include
terminal boxes with six points. The points can
be connected together with links in one of two
ways to suit one of the two rated voltages.

Delta is represented by a triangle and star by a
Y (Wye).

Dual voltage motor nameplates include
symbols to represent voltage and full load
current in each configuration.

The selection of Star or Delta is not optional
and must match the supply voltage.

Parker AC10 Series Inverter (to 22kW)

Phase

Phase

Phase

Earth

Screen

Phase

Phase

Phase

Link

DELTA

STAR

Link

Earth

Screen

Summary of Contents for AC10 series

Page 1: ...a safety device All safety considerations including but not limited to Emergency Stop provision should be assessed separately and are outside the scope of this guide Parker AC10 Frequency Inverter to...

Page 2: ...nd configure a Potentiometer for remote speed control Contents Parameters Overview Parameters to set before use How to connect and configure a Run Stop switch with Forward Reverse selection Power and...

Page 3: ...tor phases determines the initial direction the motor turns Notes Important Use screened or armoured cable between the Inverter and Motor and ensure it is grounded as shown The supply must match the I...

Page 4: ...is not important They should be connected to the terminals marked L1 R L2 S and L3 T as shown In some cases these terminals may be marked L1 L2 and L3 only Notes The order of the three motor phases d...

Page 5: ...hanging from Delta to allow the motor to be changed back in future For safety purposes Star shown opposite is the default configuration for small motors usually to 3kW and is sometimes known as two at...

Page 6: ...power down 0 F228 Application Selection Defaults below are based on F228 0 Default is will suit most applications 5 different application Macros available 0 F801 Rated Motor Power kW Rated kW of the...

Page 7: ...roup mode the DGT digit lamp is not illuminated 6 2 Select the required parameter group Use the up and down keys to select parameter group F800 6 3 Select the required parameter Press the 0 stop key t...

Page 8: ...used to cycle through other values such as motor rpm current A and voltage U Parker AC10 Series Inverter to 22kW 7 1 Select the speed reference Press the M key repeatedly until the speed reference is...

Page 9: ...Motor Power kW Rated kW of the motor Set to match the motor nameplate eg 2 2kW 2200 F802 Rated Motor Voltage V Rated Voltage of the motor Set to match the motor nameplate eg V 230 F803 Rated Motor Cu...

Page 10: ...rated from 2kOhm to 5kOhm can be used eg 4 7kOhm The default output frequency at 0V is the minimum frequency of the Inverter To change this edit Parameter F112 The default output frequency at 10V is...

Page 11: ...on opposite When a connection is made between terminals 24V and DI3 the motor will run forward When terminals 24V and DI4 are connected the motor will run in reverse The selected direction of rotation...

Page 12: ...15 set to to select Run Fwd 15 F319 DI4 terminal function setting Default is 16 set to to select Run Rev 16 11 1 Parameters to change for remote Run Stop Two suitable 2 position NO Normally Open swit...

Page 13: ...rse Select Open Forward Closed Reverse 16 12 1 Parameters to change for remote 3 wire control Note that the Forward Reverse switch can be used to set the direction when the motor is stopped or running...

Page 14: ...or manual issued by the manufacturer for details 13 2 Connecting the Resistor The braking resistor may get hot during operation Ensure that it is suitably mounted so any heat generated will not affec...

Page 15: ...0 F800 etc Use the up and down keys to select parameter group F100 14 2 Select parameter group 1 Note In parameter group mode the DGT digit lamp is not illuminated Use the up and down keys to select p...

Reviews: