Installation
Inverter should be installed vertically, as shown in
Figure 7-1. Sufficient ventilation space should be
ensured in its surrounding.
Clearance dimensions (recommended) are
available from Table 7-1 Clearance Dimensions for
installing of the inverter. Space between 2 drives
25mm.
IP20
Frame
Part Number
External Dimension
AxBxH (H1) [mm]
Weight [lb/
kg]
Mounting
Size (WxL)
Mounting
Bolt
1
10G-X1-XXXX-XX 80×135×138 (153)
2.76/1.25
70×128
M4
2
10G-X2-XXXX-XX 106×150×180 (195)
3.88/1.76
94×170
M4
3
10G-43-XXXX-XX
138×152 ×235 (250)
6.53/2.96
126×225
M5
4
10G-44-XXXX-XX
156×170×265 (280)
10.80/4.9
146×255
M5
5
10G-45-XXXX-XX
205×196 ×340 (355)
16.53/7.5
194×330
M5
Note: H is the size of inverter without grounding plate. H1 is the size of inverter with grounding plate.
Model
Clearance Dimensions
IP20 Plastic
A
≥150mm
B
≥50mm
IP20 Metal
A
≥200mm
B
≥100mm
IP66
A
≥150mm
B
≥12.5mm
IP20 Plastic Enclosure - Frame 1-5
Dimensions
2-5
Installation and Dimensions
Summary of Contents for AC10 series
Page 13: ...Dimensions 2 8 This page intentionally left blank...
Page 15: ...Connections 2 10...
Page 19: ...Panel Display IP20 Units 3 4 Items and Remarks Displayed on the Panel...
Page 23: ...Menu Organization IP66 Units 3 8 Items and Remarks Displayed on the Panel...
Page 33: ...The Default Applications 8 2 Application 1 Basic Speed Control...
Page 34: ...8 3 The Default Applications Application 2 Auto Manual Control...
Page 35: ...The Default Applications 8 4 Application 3 Preset Speeds...
Page 36: ...8 5 The Default Applications Application 4 Raise Lower Trim...
Page 37: ...The Default Applications 8 6 Application 5 PID...