Application Notes:

700-00028-0, DFC-4 Fan Driver Unit.

Fan drive systems ( FDS ) are an important part of the protection needed for the engine and associated 

peripheral components to ensure maximum reliability, productivity and long term operation. The FDS 

offered by Parker will save fuel, reduce emissions ( particle and noise ) and increase application 

productivity by only operating the fan when required and matching the fan speed to the heat load that 

requires dissipation.

For fail-safe operation, Parker strongly recommends that the hydraulic valves used are of the ‘Negative 

logic’ variety. This means that the valve gives less pressure for an increasing drive current. This choice 

results in full pressure and therefore defaults to full fan speed in the event of the electronic controller being 

dis-connected or disabled.

There are situations where full fan speed with no drive current may not be optimal so the controller in this 

manual allows the user the choice of either ‘negative logic’ or positive logic ( Increasing pressure with 

increasing current ) valves by a simple link selection under the units protective cover.

Because the controller is designed to connect directly to the engine ECU, all the decisions on ramp rates, 

proportionality, slope angle e.t.c. are already calculated for us. This means that adjustment of the controller 

is simple with only three potentiometers –

„

Dither frequency ( which is needed to ensure correct, repeatable and smooth valve operation ).

„

I Min ( which sets the Max fan speed on Negative logic valves or Min fan speed in positive logic circuits ).

„

I Max (which sets the Min fan speed on Negative logic valves or Max fan speed in positive logic circuits). 

To maintain operational integrity and prevent unauthorized adjustments once set, the assembly of the 
driver is such that the enclosure containing the electronics ( electronic printed circuit board and 
components are fully isolated from the casing ) must be firstly securely attached to the unit lid by the 4 x 
countersunk screws provided. Once this is done, the entire controller can then be mounted to the 
designated flat surface using the 4 x slotted openings in the lid. 

The controller electronics are fully encapsulated in black flame proof resin to allow continuous operation in 
adverse conditions while protecting them from vibration and external environmental influences.

This unit has been designed to meet all the current EMC requirements and is a well proven control circuit 
with many years of field and time proven operation.

Important Note:-

Please be aware that fan systems can start without warning 
and may cause personal injury if precautions are not taken 
and safe working practices observed.

Summary of Contents for 700-00028-0

Page 1: ...1 Fan Controller Unit 700 00028 0 Application and Information Manual DFC 4 12 24V Direct Connect option Publ 700 00028 0 ver6 February 2006...

Page 2: ...and or advice should be sought from your local distributor or from Parker internal sales departments This driver unit has been designed to interface and operate with Wide supply range 10VDC to 32VDC...

Page 3: ...t under full load 8 Allow wires TO or FROM the unit to short circuit to each other or chassis cabinet e t c 8 Attempt to use this unit in areas of intense RF without adequate screening measures 8 Disc...

Page 4: ...y slope angle e t c are already calculated for us This means that adjustment of the controller is simple with only three potentiometers Dither frequency which is needed to ensure correct repeatable an...

Page 5: ...wer supply to the controller is removed Recommended Parker valve is the ERA121C30 3000psi operation other values are available please consult the IHD catalogue Adjustment Guide NON NON INVERSE INVERSE...

Page 6: ...TE For operational safety if the input PWM signal is below approx 5 the output to the valve is OFF 0 20 40 60 80 100 110 Output Current mA 0 20 30 40 50 60 70 80 100 PWM input 10 90 Output Characteris...

Page 7: ...ommand Input Value 10V 30V 5 to 95 PWM typical range 10 Command Input Frequency 20 to 125Hz 11 Available adjustments I Max I Min Dither Frequency adjust 12 Dither Frequency coil output Preset to 200Hz...

Page 8: ...varying the command signal 15 Set command to maximum PWM 16 Isolate the controller from the power Controller 700 00028 0 is now set and ready for operation 17 Attach the lid to the main controller uni...

Page 9: ...nd signal 16 Set command to minimum PWM 17 Isolate the controller from the power Controller 700 00028 0 is now set and ready for operation 18 Attach the lid to the main controller unit carefully ensur...

Page 10: ...V max supply input PWM output PWM 0V output Emergency Fan MINIMUM SPEED relay configuration NC NO 1 2 Closing the relay will force the input to 24V supply voltage and the fan will be controlled to ful...

Page 11: ...ightweight Aluminum alloy Housing Colour Eggshell Black Surface Finish Powder coated Unit size See above size detail drawings Unit Weight Approx 400 grams including Encapsulation material Cable Wire e...

Page 12: ...12 Parker Hannifin Corporation Fan Drive Systems 14249 Industrial Parkway Marysville OH 43040 Customer Service Department Tel 937 644 4435 Fax 937 642 3639 www parker com hydraulics fandrive...

Reviews: