10
6053/6055 Modbus Plus Communications Interface
590+
Set 1 : Write to TechBox
Byte
Description
Drive Tag Number
Range
0, 1
Remote Sequence
536
1
0000 - FFFF
2 Bit-field:
Bit
Number
0
Aux
Start
161 Binary
1
Aux
Jog
227 Binary
2
Aux
Enable
168 Binary
3
User Defined Logic 1
(miniLINK LOGIC 1)
346 Binary
4
User Defined Logic 2
(miniLINK LOGIC 2)
347 Binary
5
User Defined Logic 3
(miniLINK LOGIC 3)
348 Binary
6
User Defined Logic 4
(miniLINK LOGIC 4)
349 Binary
7
User Defined Logic 5
(miniLINK LOGIC 5)
350 Binary
3 Reserved
4, 5
Setpoint Sum 1 Input 0
(Speed Reference %)
309 ±
100%
6, 7
User Defined Value 1
(miniLINK VALUE 1)
339 ±
100%
8, 9
User Defined Value 2
(miniLINK VALUE 2)
340 ±
100%
10, 11 User Defined Value 3
(miniLINK VALUE 3)
341 ±
100%
12, 13 User Defined Value 4
(miniLINK VALUE 4)
342 ±
100%
1.
Tag 536 functions only when Rem Seq Enable (tag 535) is true.
2.
Refer to Appendix C for Sequence Status and Remote Sequence details.
3.
The output of Setpoint Sum 1 function block is connected directly to the Speed Loop block
by default.