6053/6055 Modbus Plus Communications Interface
Operation Enabled
Same as the RUNNING output parameter of the SEQUENCING LOGIC function block.
Fault
Same as the TRIPPED output parameter of the SEQUENCING LOGIC function block.
(Not) Voltage Disabled
If in Remote Comms mode, this is the same as Bit 1 of the COMMS COMMAND parameter.
Otherwise it is the same as the NOT COAST STOP input parameter of the SEQUENCING
LOGIC function block.
(Not) Quick Stop
If in Remote Comms mode, this is the same as Bit 2 of the COMMS COMMAND parameter.
Otherwise it is the same as the NOT FAST STOP input parameter of the SEQUENCING
LOGIC function block.
Switch On Disable
Set (=1) only when in START DISABLED state; refer to the Software Product Manual,
HA465038Uxxx, Section 4 : Sequencing Logic States.
Remote
This bit is set (= 1) if the Inverter is in Remote mode AND the parameter REMOTE COMMS
SEL of the COMMS CONTROL function block is Set (= 1).