![Parker 512C Series Technical Manual Download Page 30](http://html.mh-extra.com/html/parker/512c-series/512c-series_technical-manual_755624030.webp)
11-1
Technical Specifications
512C Series Converter
T
ECHNICAL
S
PECIFICATIONS
Environmental Requirements
Enclosure
Chassis Mounting IP00.
Operating Temperature
0 to +40oC. (Derate 1.5%/Degree above
40oC)
Humidity
85% R.H. at 40oC. (non condensing)
Altitude
Above 1000m derate at 1% / 100m.
Storage Temperature
-25oC to +55oC
Transport Temperature
-25oC to +70oC
Climatic Conditions
Class 3k3, as defined by EN50178 (1998)
Operating Conditions
Installation Category
Overvoltage Category III
Pollution
Pollution Degree 2.
Maximum Supply Voltages
(Derived from a 3-phase
480Vac L - L
Non earth referenced (IT)
or earth referenced (TN)
supply)
480Vac L - N
Earth referenced (TN)
Wiring
•
Control Cabling 0.75sq.mm minimum.
•
Power cable to be minimum 600V AC rated at 1.5 x armature current.
•
High speed semi-conductor fuses of the correct rating are recommended controller semi-
conductor protection, as the 512C is not internally fused. The suitability of the semi-
conductor fuse branch protection should be decided by the installer.
•
Ensure a protective earth connection is made compatible with the rating.
•
Isolated control wiring should not be run close to the power cabling. If screened cables are
used (recommended on setpoints and tachogenerators) connect screens to earth only at
controller end.
•
Parker SSD Drives can supply fuse assemblies which can be bulkhead mounted and also act
as convenient supply isolators.