![Parker 506 Series Product Manual Download Page 36](http://html.mh-extra.com/html/parker/506-series/506-series_product-manual_755622036.webp)
Technical Specification
7-3
506/507/508 - HA389427
EMC Technical Ratings
Immunity
Port
Phenomenon Test Standard Level
Criterion
Generic
Standard
Enclosure
Port
ESD
RF Field
BS EN61000-
4-2(1995)
8kV AD
10V/m,1kHz
AM
Self Recovery
No Change
EN50082
-1
(1992),
Power
Ports
Fast Transient
Burst
BS EN61000-
4-4(1995)
2kV Self
Recovery
and
EN50082
Signal &
Control
Fast Transient
Burst
BS EN61000-
4-4(1995)
2kV Self
Recovery
-2
(1995)
Power
Interfaces
Fast Transient
Burst
BS EN61000-
4-4(1995)
2kV Self
Recovery
Emissions
These levels of performance are achieved when installed as
specified with the recommended Supply Filter.
* Achieved with up to 50m of motor cable.
Port
Phenomenon Test Standard Level
Generic Standard
Enclosure Port Radiated
EN55011
Class B
EN50081-1 (1992)
Power Port
Conducted
EN55011
Class B*
EN50081-2 (1994)