Overview of the 506/507/508
2-1
506/507/508 - HA389427
3
O
VERVIEW OF THE
506/507/508
Figure 2.1 Recognition Drawing
ON
1 2 3 4
Auxiliary Inputs
Customer
Personal Switches
Indicators
Control
56
Pots
Mains
Switch
220/240V
110/120V
1 2 3 4
User Supplied Safety Components
Speed /
Torque Potentiometer 10K Isolated spindle and insulating knob
Switch
Rated for input supply voltage.
Note:
Safety Components provide Isolation for the User. These
components should be selected to provide a double insulated (or
reinforced) isolation boards for the user suitable for the input
supply voltage used. The product is designed for use in a
pollution degree 2 environment, overvoltage category III,
enclosure mounted. (Refer to EN61010, IEC664 or EN50178
for more information regarding the correct selection of these
components).
Optional Ancillary Components
EMC Filter 18A ac(12A dc)
CO389115