Chapter 6 – Internal Access and Lubrication
Internal Access Procedure
Tools Required:
Ball driver or Allen Key
Procedure:
The following procedure outlines the steps required to access the mounting holes
located inside the unit.
•
Remove the strip seal clamps and carefully pull back strip seal.
•
CAUTION:
Edges of strip seal are very sharp. Use caution while handling the strip seal.
•
If you are using a round ended ball driver you will be able to tighten/loosen the base mounting screws.
•
If you are using an Allen key you will need to remove the side covers. Remove the screws on the bottom
of the side cover and slide off the side. You will now be able to access the base mounting screws with
the Allen key.
Square Rail Bearing Lubrication
The square rail bearings are lubricated for the life of the table. No further lubrication is required.
Ground Ballscrew Lubrication