Parker Hannifin Corporation – UTS User Manual
9
6
Installation Guidelines
Operating Conditions
The UTS should not be submerged under any liquid without added protection. The operating temperatures for
the sensor are -40 to +85°C.
CAN
The UTS uses CAN messages to report its angular position. All messages are SAE J1939 Proprietary B PGN's
except the address claim request and response which are SAE J1939 standards. The UTS is compatible with a 250
kbps CAN baud rate, qualifying it as a “High-Speed” CAN sensor. Per ISO 11898-2, the linear bus must be
terminated with two 120
Ω
resistors at the ends of the transmission lines. Termination resistors are not
provided with the system. External CAN termination is required. Be sure to follow SAE J1939 standards when
creating the harness that the sensor connects to.
For a list of the default settings of the UTS refer to Table 7.4.1.
Power Supply Requirements
Table 6.3.1 shows the power supply requirements for the UTS. The UTS operates in 12V or 24V systems and can
operate from 6.5 V to 48 V with a regulated voltage supply.
Table 6.3.1: UTS Power Supply Requirements
Parameter
Value
Operating Voltage
+6.5 to +48 Vdc
Input Current
9 mA at 12V typical
6mA at 24V typical
Circuit Protection
Reverse Polarity
-48 Vdc
All Pins - Short to +V
BAT
+32 Vdc MAX
Transients
See ISO 7637-2,-3
Connector
The UTS uses the Deutsch DT series connector type. Technical details are listed below.
Mating Connector:
DT06-4S
W4S
1062-16-0144
Figure 6.4.1: UTS Mating Connector
Figure 6.4.2: UTS
Connector Diagram