Insufficient Bubbler Flow:

 

Check that the shut-off valve is wide open.  Verify minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve body.  

Clean rubber orifice in flow control located below frost line in bushing between barb fitting and valve.

No Flow:

 

 Check for leaks in the air tubing going from the push button to the valve.  Make sure the air tubing compression nut is hand tight.  Disconnect air tube from 

push button.  Place finger over air outlet. Push button to test diaphragm.  Tighten diaphragm cap screws.  Replace diaphragm if necessary.

Continued Insufficient or Varied Height of Bubbler Flow:

 Replace flow control.

 Check for kinks in the tubing.

 Remove the cleanout plug from the PVC column. Remove the valve assembly from the  PVC column by carefully pulling up on the strap and connecting tubing at the 

same time. Pressure test the valve assembly for leaks. Check stream height from the bubbler. Stream height is factory set at 35 PSI. If supply pressure varies greatly 

from this, adjust the screw on the regulator (Item 11, Page 6, Fig. 4). Clockwise adjustment will raise stream and counter-clockwise adjustment will lower stream. For best 

adjustment stream height should be approx. 1-1/2" (38mm) above the bubbler guard. Replace the valve into the PVC column. Make sure the supply hose coils into the 

bottom of the PVC column without any kinks and double check that the valve is positioned fully at the bottom of the PVC column. Cap the PVC column.

Continuous Bubbler Flow:

 

Insure that push button is not obstructed and springs back to normal position. Remove four screws which secure plastic diaphragm block 

to valve body.  Pull plastic and rubber diaphragm assembly out of valve body.  Locate tiny hole in rubber diaphragm just under lip of plastic part.  Clean debris from this 

hole.  Inspect valve seat for grooves.  If valve seat was OK and diaphragm hole was free from debris, inspect rubber button located at center of floating steel disc in valve 

diaphragm block assembly.  If button is worn, turn disc over or replace it.  If diaphragm and seats are in good condition, stretch spring slightly.  Spring is located behind 

floating stainless steel plate.  Insure that air bleed port on valve plastic block assembly is not plugged.

            

TROUBLESHOOTING AND MAINTENANCE

17

Vandal-Resistant 

Bubbler Detail 

FIG. 8

BASIN

FIG. 9

STREAM HEIGHT ADJUSTMENT:

Stream height is factory set at 35 psi. If supply pressure 

varies greatly from this, insert a small straight bladed 

screwdriver through the access hole in the center of the 

push button and turn the adjustment screw. Clockwise 

adjustment will raise the stream and counterclockwise 

adjustment will lower the stream. For best adjustment, 

the stream should be approximately

 

1 1/2" above the 

top of the bubbler. (See Fig. 9)

Summary of Contents for 605wf100-2

Page 1: ...sure you install these models easily and correctly PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTINGTHE INSTALLATION CHECKYOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING ELECTRICAL AND OTHER APPLIC...

Page 2: ...coil any excess tubing or it will cause the valve to malfunction Do not pull up on lines coming out of the PVC column This raises the water valve above the frost line Use the nylon strap ref Item 10...

Page 3: ...PIPE TRIM TO DESIRED LENGTH SUPPLIED BY INSTALLER PVC 8 x 8 x 4 COMBINATION Y 1 8 BEND REDUCING ASSY SUPPLIED BY INSTALLER 4 PVC PIPE SUPPLIED BY INSTALLER 4 102mm 4 PVC 1 4 BEND SUPPLIED BY INSTALLE...

Page 4: ...L CODES 6 1 2 13mm DIA HOLES EQUALLY SPACED ON A 12 305mm BOLT CENTER SEE DETAIL A CONCRETE SLAB A 4 102mm O 14 356mm 8 203mm 30 762mm 44 1118mm 14 9 16 371mm 64 1626mm 3 76mm 10 254mm O 1 1 4 DRAIN T...

Page 5: ...O D tube Label E into the 1 4 union provided with valve assembly Insert the 1 4 O D water line coming from the fountain into union Trim any excess length Step 4 Insert the 1 4 O D tube Label G into t...

Page 6: ...PAGE 6 2 3 11 4 12 5 10 FIG 4 FIG 5 6 6 13 5 14 14...

Page 7: ...Holder Regulator Nut Poly Tubing 1 4 Cut To Length To Bubbler Poly Tubing 1 8 Cut To Length To Actuator Canister Nylon Strap 6 ft Air Gap Assy Fitting 1 2 Union w Strainer Kit 1 0 GPM Regulator BF On...

Page 8: ...Make sure the supply hose coils into the bottom of the PVC column without any kinks and double check that the valve is positioned fully at the bottom of the PVC column Cap the PVC column Continuous Bu...

Page 9: ...eplate Insert only 4400BFFR Nameplate Insert only Kit BF Waterway Nipple Gasket Tubes Ftgs Kit Nozzle Aerator Gasket Pin Key Kit Aerator Key Kit Blank Bottle Filler Trim Kit LK4400BF Bottle Filler Tri...

Reviews: