background image

2

GENERAL

TA

  series  are  four-channel  power  amplifiers  designed  for  fixed  installations. The 

series includes the following amplifier models:

– 

TA604

 – 4 х 

1

50

W

 

at 

4

 Ohm load;

 

TA604L

 – 4 х 150

W

 

for

 70

V

 

or 

100

V line operation

;

 

TA604D

 – 4 х 150

W

 

at 

4

 Ohm load

with

 

DSP

;

 

TA604DL

 – 4 х 150

W

 

for

 70

V

 

or 

100

V line operation

,

 with

 

DSP

.

ATTENTION!

Unless specified otherwise, the word «amplifier» hereinafter applies 

  

to any of the above models.

WARNING!

Make sure to take all precautions where required.

Please, follow all instructions and guidelines.

To avoid any risk of electrical shock and/or fire hazard, please, do not expose 

this unit to rain or moisture. Do not use this unit near open water.

Use dry cloth to clean the unit.

Do not block fan vents.

Do not place the unit near heating radiators, furnaces or other heat-emitting 

devices.

Do not connect this unit to an ungrounded power supply line.

Protect the power cord against damage.

Disconnect the unit from power supply in case of thunder or during downtime.

In case of malfunctioning, caused by water or any other foreign matter inside or 

when the unit has been dropped, or the power cord has been damaged, or the unit 

has been found

 

faulty, please, consult qualified personnel.

Summary of Contents for TA Series

Page 1: ...FOUR CHANNEL INSTALLATION POWER AMPLIFIERS TA series TA604 TA604L TA604D TA604DL Owner s Manual...

Page 2: ...nnected to the unit in operation CAUTION The high sound pressure level of speaker systems generated by high output power delivered by the amplifier may be hazardous to your hearing Please take adequat...

Page 3: ...of damage please contact your local dealer Keep the shipping carton and all packing material as you may require them for reshipment of the unit SUPPLY KIT PowerAmplifier 1 pc Power Cable 1 pc USBA US...

Page 4: ...s and guidelines To avoid any risk of electrical shock and or fire hazard please do not expose this unit to rain or moisture Do not use this unit near open water Use dry cloth to clean the unit Do not...

Page 5: ...Built in DSP engine installed into amplifier ensures digital filtering separation into frequency bands optimal EQ time alignment as well limiting and speakers overload protection The parameters set up...

Page 6: ...system disables the respective pair of amplifier channels The CLIP LED goes on and the SIGNALLED of the affected pair of channels goes off As soon as the amplifier cools down the affected channels gra...

Page 7: ...h 2 GND Hi Pass Filter 45Hz INPUT Ch1 GND Hi Pass Filter 45Hz CLIP THERM PROT CLIP Ch 3 LEVEL Ch 4 LEVEL INPUT Ch 4 GND Hi Pass Filter 45Hz INPUT Ch3 GND Hi Pass Filter 45Hz CLIP THERM PROT CLIP N C N...

Page 8: ...LEVEL INPUT Ch 2 GND Hi Pass Filter 100Hz INPUT Ch1 GND Hi Pass Filter 100Hz CLIP THERM PROT CLIP Ch 3 LEVEL Ch 4 LEVEL INPUT Ch 4 GND Hi Pass Filter 45Hz INPUT Ch3 GND Hi Pass Filter 45Hz CLIP THERM...

Page 9: ...ST DSP Ch 3 GND GND OUTPUT POST DSP Ch 4 Ch 4 LEVEL Ch 3 Ch 2 Ch 1 THERM THERM CLIP PROT CLIP CLIP PROT CLIP Power amplifier Ch 1 Ch 2 Ch 3 Ch 4 V G4 G3 V G2 G1 GND GND GPI GPI N C N C SPEAKER OUTPUTS...

Page 10: ...n 1 Out 3 Out 2 In 2 Out4 USB Port Ch1 INPUT Ch 2 OUTPUT POST DSP Ch 3 OUTPUT POST DSP Ch 4 Ch 4 LEVEL Ch 3 Ch 2 Ch 1 THERM THERM CLIP PROT CLIP CLIP PROT CLIP Power amplifier Ch 1 Ch 2 Ch 3 Ch 4 V G4...

Page 11: ...tching off CLIP clip LEDs for Channels 1 2 3 and 4 respectively They indicate overload condition causing distortion activation of DSPlimiter for TA604D TA604DL POWER power supply switch PROT protectio...

Page 12: ...nced inputs Euroblock connectors for channels 4 3 2 1 3 7 4 6 8 10 1 2 5 9 GND GND SPEAKER OUTPUTS 0 10 Ch4 Ch3 Ch4 Ch3 INPUTS Ch4 Ch2 Ch1 AIN G 0 Ch3 AIN G 0 Ch2 AIN G 0 Ch1 AIN G 10 10 10 GND GND Ch...

Page 13: ...PI G PI G model TA604D POWER AMPLIFIER Serial No 12 9 10 11 2 11 4 5 6 7 8 3 1 10 11 12 GND GND GND GND SPEAKER OUTPUTS 0 10 USB G4 G3 V G2 G1 V Ch4 Ch3 Ch4 Ch2 Ch1 AIN G 0 Ch3 AIN G 0 Ch2 AIN G 0 Ch...

Page 14: ...sary to leave 1U empty space above or below the amplifier AC POWER REQUIREMENTS The amplifier is supplied with a three wire grounded AC power cord and should be plugged into a standard 3 wire grounded...

Page 15: ...ance should be not less than 8 Ohm Balanced input signal is applied to channels 1 and 2 3 and 4 simultaneously at bridge connection of these channels Gain control is performed via controls of both cha...

Page 16: ...l Loudspeakers Connection to input on 100V line for channels 4 and 3 Loudspeakers Connection to input on 100V line for channels 2 and 1 TA604L Four channel Mode connection on 70V line SPEAKER OUTPUTS...

Page 17: ...are connected to the respective channels The polarity of connection is shown on the rear panel near corresponding sockets Nominal impedance should be not less than 4 Ohm Balanced input signal is appli...

Page 18: ...OM 70 V 1 00 V GND GND Channel 1 Input Signal Channel 2 Input Signal Output Lines are connected to COM and 100V sockets of corresponding channels Balanced signal of each channel is applied to channels...

Page 19: ...dual control for each channel pic 1 and general connection for pairs of channels 1 2 and 3 4 for BRIDGE mode pic 2 are shown below GND GND GND GND USB G4 G3 V G2 G1 V INPUTS POST DSP OUTPUTS Ch2 Ch1 C...

Page 20: ...EUROBLOCK plug using a flat blade screwdriver turn screw clockwise to clamp wire tightly Wiring Connection to EUROBLOCK Connectors Input Cable Shield GND Cold Hot Output Cable for TA604 TA604D Output...

Page 21: ...DL 100Hz 20kHz HPF100Hz 24dB oct Total Harmonic Distortion 0 02 20Hz 20kHz Slew Rate 60dB 1kHz Signal to Noise Ratio 100dB unweighted Input Impedance 10kOhm balanced Sensitivity 0 775V Power Requireme...

Page 22: ...20 482 440 max 290 300 465 32 44 56 282 22 DIMENSIONS...

Page 23: ...R PARK AUDIO II Ltd Vinnytsia Ukraine www parkaudio ua e mail park parkaudio ua...

Reviews: