PARK AUDIO RX Series Owner'S Manual Download Page 5

3

DESIGN FEATURES

Physical Design

The  amplifier  is  enclosed  in  a  metal  (steel)  case  of  2U  height.  The  amplifier  is 

designed to be installed into a standard 19" rack.

The amplifier must be fixed at four points, when installed in the RACK 19 "(two points in 

front and two at the rear).

Power Supply Unit

Two independent switch-mode PSU. Individual for each pair of channel.

Cooling System

Forced, cooling rate smooth adjustable system.

Two powerful fans. Backward air flow direction.

Dust Filter

Two removable filters are located on the front panel under protective covers. 

Covers  can be removed and installed without the use of any tools.

Power Amplifier Units
RX9d

 amplifier is based on a modern, high performance 

D

 class topology. 

This topology provides high efficiency, low heat generation and large output power  At 

the same time, the high switching frequency of the output stage (450 kHz) provides sound 
quality comparable with the best analog amplifiers.

Analog inputs

The amplifier is equipped with four balanced analog inputs (

XLR

 female).

The use of balanced inputs provides for an essential reduction of the environment-

induced hum and noise interference with long input connecting cables.

For DSP processing, the analog signal is converted to digital using four 24-bit A/D 

converters, operating at 96 kHz. The dynamic range of A/D and D/A converters is 120 dB.

AES inputs

Inputs of channels 1 and 2 can be switched to digital input mode.

A  digital  AES/EBU  two-channel  audio  signal  can  be  applied  to  each  input.  Sound 

signals  can  be  sent  to  an  amplifier  from  a  digital  mixing  console  or  other  device,  that 
generates a digital audio signal AES/EBU (AES3). The AES/EBU inputs have balanced 
transformers  and  are  protected  against  static  electricity.  Built-in  sample  rate  converters 
support a wide range of input formats (16-24 bit / 44.1-192 kHz), converting any of them into 
internal format 24bit / 96kHz.

ETHERNET connectors

Two equivalent ports for connection to the 

ETHERNET

 network.

Provide the ability to configure and remotely control the amplifier over a network, using 

the NetControl software. The built-in router allows you to connect multiple amplifiers in 
chain.

Line Outputs

Four 

XLR

 connectors (male).

Provide  the  possibility  of  parallel  connection  of  several  amplifiers,  using  standard 

signal cables.

Summary of Contents for RX Series

Page 1: ...series 9d FOUR CHANNEL PROFESSIONAL SWITCHING POWER AMPLIFIER Owner s Manual...

Page 2: ...ACCESSORIES 1 Power Cord 1 pc 2 Dust filter 2 pcs 3 Owner s Manual 1 pc 4 Warranty 1 pc...

Page 3: ...AUTION The amplifier can yield dangerous output voltage Do not touch the non insulated cable parts connected to the unit in operation CAUTION The high sound pressure caused by the high output signal a...

Page 4: ...ck fan vents Do not place the unit near heating radiators furnaces or other heat emitting devices Do not connect this unit to an ungrounded power supply line Protect the power cord against damage Disc...

Page 5: ...lanced inputs provides for an essential reduction of the environment induced hum and noise interference with long input connecting cables For DSP processing the analog signal is converted to digital u...

Page 6: ...the tools for group control of many amplifiers simultaneously The amplifier can be supplied with pre formed library of passive speakers Software is designed for group control of a large number of ampl...

Page 7: ...sured for each pair of channel by individual power supply units which are disabled in the event of output DC voltage or any powerful LF fluctuations In case the protection system becomes active on all...

Page 8: ...power supply Only the protection system stand by power supply unit remains in operation The system activates whenever the mains voltage exceeds 265V The amplifier automatically resumes operation after...

Page 9: ...AMPLIFIER BLOCK DIAGRAM 1 1 2 2 1 Ch1 AES1 2 INPUT Power amplifier Ch 1 1 2 2 THRU THRU Ch1 Ch2 OUTPUTS TO SPEAKERS Ch2 Ch 2 Ch 3 Ch 4 THRU THRU Ch3 Ch4 Ch4 Ch2 AES3 4 Ch 3 Ch 4 INPUT INPUT INPUT DSP...

Page 10: ...ers activation LEDs CLIP overload LEDs for channels 1 2 3 and 4 Indicating overload and distortion occurence 2 x 20 characters LCD display DSPCONTROL encoder knob for the menu navigation and parameter...

Page 11: ...assignment are marked on the amplifier rear panel MAINS IN mains cable connector THRU line outputs Used for sending the input signal to another amplifiers In analog signal mode THRU connectors are pa...

Page 12: ...reased damping factor and possible fire hazard Since the power applied to the loudspeaker is of primary concern in system design we have included the table below to allow you determine the appropriate...

Page 13: ...of both channels via a single cable use SpeakON NL4FC CAUTION Never attempt to jumper or otherwise link up any pins of output connectors 2 1 3 2 1 3 1 1 1 2 1 2 1 2 1 2 XLR Wiring male XLR Wiring fema...

Page 14: ...e amplifier to a household mains If connected to weak power supply mains the output power of the amplifier may be reduced producing the so called feeble bass effect or the power supply line may be dam...

Page 15: ...tely STORE PRESET current setting store as user preset into Preset Library in one of the memory cells 1 92 SETUPIP amplifier IP address setting SELECT INPUT input mode choise analog or digital AES EBU...

Page 16: ...ed in the upper line of the LCD display Rotating the DSP CONTROL knob changes parameter with step 0 1dB The step can be changed from 0 1dB to 1dB and vice versa by short clicking DSPCONTROLknob No par...

Page 17: ...ith your nger shown in the gure below and pull it toward The locking latch must be unlocked After that carefully remove the cover and the lter A heavily dusted lter can be washed in any synthetic dete...

Page 18: ...35 dB Power Requirements 230 V 50 60 Hz Weight 12 kg Dimensions 482 mm W 96 mm H 442 mm D DSP Parameters SHARC DSP 96 kHz sampling rate 40 bit oating point ADC 120dB SNR 100 dB THD N 18 dBU Input Leve...

Page 19: ...4x2200W DIMENSIONS 482 440 max 439 442 465 76 88 96 428 12 17...

Page 20: ...PARK AUDIO II Ltd Vinnytsia Ukraine www parkaudio ua park parkaudio ua...

Reviews: