T6T VHF 100 W Transmitter
Page 6
Specification
Back to Transmitter
Main Page
Residual FM
Both modes
For a test signal of 1 kHz set at 80% modulation depth applied to the
line input of the transmitter, the unwanted peak frequency modulation
does not exceed ±500 Hz.
VOGAD
AM-Voice
The VOGAD has an operational range of 30 dB. The VOGAD can be
disabled.
AM-MSK
The VOGAD is disabled.
Mute
AM-Voice
The mute level is set at 15 dB below the average speech line level
setting. The mute can be disabled.
AM-MSK
The mute is disabled.
Differential Group Delay
AM-MSK
There is less than 60 µs differential group delay for signals in the
range 1200 to 2400 Hz.
Transmitter Control
Transmitter control characteristics are as follows:
Audio Inputs
Voice can be connected to the transmitter via the front panel microphone connector. Voice can also be
connected via the line inputs. Line level setting from -30 to +10 dBm.
PTT Time Out
The time out period is adjustable from 2 to 510 seconds in 2 second steps or it can be disabled.