Installation
Draft
Fitting an MDR into an Equipment Cabinet
During installation an MDR may have to be lifted, possibly to head height, to fit onto
telescopic slides. At least two people should be used to lift the equipment. Failure to use
sufficient people when lifting equipment can result in personal injury.
It is essential that the chosen mechanical installation provides adequate support along the
depth (front to rear) of the unit. The MDR must not be supported by the front panel; doing so
can cause damage.
The MDR can be installed on telescopic slides, or on fixed runners, within a standard 483 mm (19 inch)
equipment rack. M4 tapped holes, each 10 mm deep (see
Fig 7
) are provided on each side of the
equipment to accept the slides. Details of suitable telescopic slides are available from Park Air.
When fitted in the rack, the MDR's front panel must be secured to the cabinet’s chassis using four
M6 x 16 mm screws and plastic washers.
Fig 1
Slide Fittings
Fig 7 Slide Fittings
WARNING
Heavy Item
Caution Mechanical Support
Front
Panel
399
390.9
378.2
232.2
207.5
152.8
47.0
29.0
41.7
430
88.9
450
All measurements in mm