31-3MDR00HB
Page 30
Operation
Draft
Table 4 Analogue ACARS Functions and Parameters
Function
Adjustment Range
Factory Default
Step
Size
Frequency
118 to 136.975 MHz
118.000 MHz
25 kHz
Band edges BE1
and BE3
118 to 136.975 MHz
118.000 MHz
25 kHz
Band edges BE2
and BE4
118 to 136.975 MHz
136.975 MHz
25 kHz
Channel
1 to 100
–
1
RF power
3 to 25 W
25 W
1 W
Reference
frequency
0 to 100%
–
0.4%
LCD display
backlight time-out
15 to 120 s, On or Off
30 s
15 s
Modulation depth
5 to 95%
90%
1%
PTT
On (key) or Off (dekey)
Off
–
PTT Polarity
STD (active low) or INV (active high)
STD
–
Phantom PTT
Polarity
STD (active low) or INV (active high)
STD
–
PTT reference
voltage
+14, 0, or -14 V
+14 V
–
Audio line input
-20 to +10 dBm
-13 dBm
1 dB
TX inhibit
On or Off
Off
–
Transmit time-out
2 to 510 s, or Off
180 s
2 s
RF pre-attenuator
On or Off
Off
–
Audio line output
-20 to +10 dBm
-13 dBm
1 dB
Loudspeaker/
Headset volume
0 to 100%
30%
5%
Initiate BIT
interruptive test
On or Off
–
–
DHCP
On or Off
Off
–
IP address
000.000.000.000 to 255.255.255.255
192.168.0.2
–
IP subnet mask
000.000.000.000 to 255.255.255.255
255.255.255.000
–
Default gateway
address
000.000.000.000 to 255.255.255.255
192.168.0.1
–
Control application
TCP port number
5001 to 65535
30000
–
Summary of Contents for 6525
Page 1: ...6525 Multimode Digital Radio User Documentation Draft...
Page 8: ...31 3MDR00HB Page 8 Draft Intentionally Blank...
Page 11: ...Draft Overview...
Page 14: ...Intentionally Blank...
Page 15: ...Draft Specification...
Page 17: ...Draft Operation...
Page 36: ...Intentionally Blank...
Page 37: ...Installation...
Page 49: ...Draft Maintenance...