background image

 

SafeAir™ M-200 Pro Installation Guide 

21

 

www.parazero.com 

8.5

 

Replacing the batteries 

 

1

 

Insert the safety pin all the 
way into position. Remove 
one battery at a time by 
grabbing the battery, while 
pressing the TerminateAir 
handle.  

 

2

 

To replace the battery, slide it 
onto the TerminateAir until an 
audible click is sound.  

 

 

  

 

 

 

 

 

 

 

 

 

Summary of Contents for SafeAir M-200 Pro

Page 1: ...SafeAir M 200 Pro INSTALLATION GUIDE For systems equipped with electronic TerminateAir...

Page 2: ...0 5 3 Connecting the Parachute System to the Legs 11 5 4 Flight Preparations 12 5 5 Drone Preparations 12 5 6 Inserting the Pyro actuator 12 5 7 Inserting the parachute 15 REMOTE CONTROLLER OPTIONAL 1...

Page 3: ...nd international treaty provisions ParaZero Drone Safety Systems retains all rights not expressly granted No part of this publication may be reproduced in any form whatsoever or used to make any deriv...

Page 4: ...ely autonomous identification and activation capability using its dedicated SmartAir Pro Autonomous Trigger System 3 A DJI M200 dedicated independent flight termination system called TerminateAir The...

Page 5: ...mal weather conditions Technical Specifications Criterion Specification Expected Reaction Time Up to 50ms Minimum safe altitude 29m AGL Vertical speed of descent hover maximum takeoff weight 6 14Kg 3...

Page 6: ...pin which acts as an on off button and electrically prevents the activation of the system Do not remove the safety pin until specifically instructed to do so in this guide This manual explains how the...

Page 7: ...system 4 four washers and 4 spring washers Parachute box 4 The parachute folded between a red base and a yellow cap Tools and cables box 5 USB C cable for the SAP 6 TerminateAir cables for electronic...

Page 8: ...com 4 SmartAir Connectors Overview A 2 Stage Safety pin Stage 1 Power on off Stage 2 Pyro safety B External damper holders A Safety pin B FTS UART connector optional Vin PWM C USB C connector D Parac...

Page 9: ...e original M 200 screws with the ParaZero longer screws six total On the screws make sure to place the washer first and then the spring washer above it before inserting the screws into the landing gea...

Page 10: ...tery onto the electronic TerminateAir until it is locked in place indicated by an audible click 3 Slide the coupled battery into the drone until it is locked in place indicated by an audible click Rep...

Page 11: ...seen on the photo 3 Use the long black cable to connect between the lower port of the LEFT electronic TerminateAir unit female side and the SAP male side Notice that the white line on the connector sh...

Page 12: ...off Caution When the RC is turned off or there is no link between the RC and the receiver manual triggering is not available 3 Using the desktop application allows for firmware update automatic downl...

Page 13: ...s 1 Verify that the safety pin is inserted all the way into position 2 Turn on the drone s power 3 Disable the Upward IR sensor On your DJI GO app press the 3 dots icon on the upper right corner of th...

Page 14: ...s in its proper place Not to connect the parachute cable to the SmartAir 1 Unscrew the safety transportation capsule and take out the pyro actuator when taking out the pyro actuator from the transport...

Page 15: ...rts first Push the parachute in all the way Remove the yellow cap and Squeeze the parachute itself into the canister while removing the paper container out keep the paper container in a safe place for...

Page 16: ...SafeAir M 200 Pro Installation Guide 16 www parazero com 6 Remote Controller optional 6 1 RC System Ports Switches LED Lanyard hole Power switch Charging port Trigger switch Belt clip...

Page 17: ...rge complete 4 3x Red flashes beeps No link SafeAir might be turned off or the RC is too far from the receiver 5 Yellow beep every 20 seconds RC battery low The RC will have enough power for 15 minute...

Page 18: ...Make sure that the parachute cable is inserted 2 Try using the pyro dummy 3 Make sure that a pyro is installed 4 Contact Parazero support Flickering Yellow x1 NA RC channel is disconnected or in acti...

Page 19: ...m is positioned on a level surface Solid Red Triggered Repeating beeping pattern with increasing frequency System was triggered and parachute deployed None Flickering Red x3 Repeating 3 beep pattern S...

Page 20: ...EDs are on Go back to a safety distance of at least 5 meters 8 2 Takeoff When climbing you must climb to approximately 7 meters before the system is armed Climb until you hear a single long beep and t...

Page 21: ...8 5 Replacing the batteries 1 Insert the safety pin all the way into position Remove one battery at a time by grabbing the battery while pressing the TerminateAir handle 2 To replace the battery slide...

Page 22: ...he parachute lines or the main parachute strap Inspect the canister SmartAir connectors and the TerminateAir to make sure that there is no apparent damage If there are tears or other suspected damage...

Page 23: ...the 2 3 of the right cells under the folded parachute 6 Fold the left and right part of the folded parachute over each other Fold one side to the middle and then fold the other side on top of it It i...

Page 24: ...all the lines at the bottom of the canister on the red base so that the folded part of the main strap figure 8 shape is put first on the red base and the rest of the lines are placed above it The res...

Page 25: ...Tel 972 36885252 30 Dov Hoz Kiryat Ono Israel 5555626 www parazero com Operate Drones Everywhere Safely...