SafeAir™ M-200 Pro Installation Guide
14
www.parazero.com
5.6
Inserting the Pyro actuator
Caution
During all installation stages, be sure –
That the safety pin remains in its proper place.
Not to connect the parachute cable to the SmartAir.
1
Unscrew the safety transportation capsule and take out the pyro-actuator - when taking
out the pyro-actuator from the transport capsule you are obliged to use protective
glasses.
2
Insert the pyro-actuator into the socket in the bottom of the container, make sure you
push it all the way in.