SafeAir™ M-200 Pro Installation Guide
11
www.parazero.com
5.3
Connecting the Parachute System to the Legs
.
1
Position the parachute system
on the legs, the SAP should be
located at the rear of the
drone. Attach the four thumb
screws, four spring washers
and four washers in this order.
Tightly secure the screws
2
Insert the parachute cable
into the adjacent hole, below
the white string, as seen on
the photo
3
Use the long black cable to
connect between the lower
port of the LEFT electronic
TerminateAir unit (female side)
and the SAP (male side).
Notice that the white line on
the connector should face
downwards.
4
Connect the long black cable
to the SAP FTS (Flight
Termination System) port and
secure it to the drone’s arm
using the Velcro strap. Notice
that the white line on the
connector should face
upwards. Make sure that the
rotors may spin freely without
any contact with the
parachute system
Notice
For M-210 It is recommended to install the extended GPS module provided.