REAR PANEL CONNECTIONS & SETTINGS 

Connection Precautions

Disconnect the AC cord before making or changing any connections.
Make sure there is no strain or tension on any wires that could cause them to pull loose.

Note:

 HDMI connections in particular are not as mechanically robust as many others. It is easier 

for an HDMI plug to pull out of an HDMI jack, so we recommend you anchor the HDMI cables 
so their plugs are gently pushed against the Zhd HDMI jacks.

HDMI In (Input) 1-5 Jacks 

Attach the HDMI cable from your sources to the HDMI Input jacks.  
All five inputs have identical characteristics.

HDMI Output Jack

Attach the HDMI output jack to your HDMI-equipped TV or display device.

IR Remote In Jack

Your Zhd accepts the infrared signal of any popular infrared repeater system to facilitate remote 
control operation from another room or when it is installed within a closed cabinet.
This connector is a 1/8” (3.5 mm) two conductor mini jack; its center conductor (plug tip) is + and 
its outer conductor (plug sleeve) is – .

Note:

 The Zhd IR Remote input does not require an amplified IR connecting block, unlike 

Parasound Surround Controllers.

IR Remote Loop Jack

The IR Remote Loop jack passes along the signal 
received at the IR Remote In jack to the next compo-
nent which is IR controlled. It is provided as a courtesy 
to make your installation easier and neater.

RS-232 Control Port

This is used for linking your Zhd to your Parasound 7.1 Channel Surround Controller, a computer, 
or a house control system, such as Crestron or AMX. This is a two-way communication port 
with full unsolicited feedback. The complete RS-232 protocol can be found on our website at 
www.parasound.com.

Note:

 You must use only the “null modem” (crossover) cable supplied with the Zhd or an  

equivalent cable to link to a Parasound Surround 7.1 Channel Surround Controller. You may only 
use a “straight-through” (non-crossover) cable with a computer or house control system such as 
Crestron or AMX. The Zhd is not supplied with a straight-through cable. 

AC Inlet

Double check that Zhd’s AC Voltage switch is set correctly for the AC line (mains) voltage  
in your region 

before

 before you install the unit and before you connect its power cord.

Note:

 The AC power source should be constant (unswitched) so the Zhd is always on  

and ready to pass the HDMI signal on to your TV.

4

Summary of Contents for Zhd

Page 1: ......

Page 2: ...ong grounding plug This plug will only fit into a grounding power outlet If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding plug 11 Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them 12 Lightn...

Page 3: ...lications 2 115 230v AC Selector Switch 3 Rack Mounting 3 Rear Panel Connections and Settings 4 Operating the Zhd 5 Operation by RS 232 6 If You Require Assistance 7 Warranty Repair 7 Specifications 8 TABLE OF CONTENTS 1 ...

Page 4: ...ss you wish to operate it manually with its front panel buttons Please read this manual thoroughly before you begin installation Unpacking Carefully unpack your Zhd and these accessories Detachable AC power cord Remote control handset with two AAA batteries RS 232 control cable with DB9 connectors for use with Parasound 7 1 Channel Surround Controllers only not for use with other Parasound models ...

Page 5: ...or 230v Rack Mounting The Zhd occupies only half the width of a single rack space in a standard 19 equipment rack For rack mounting you can fasten it to another Parasound Z Custom model by using the Parasound SBS Side by Side mounting kit You can also mount a single Zhd in the rack with the accessory Zblank panel The SBS includes four rack mount bolts plus four pairs of plastic shoulder washers Th...

Page 6: ... amplified IR connecting block unlike Parasound Surround Controllers IR Remote Loop Jack The IR Remote Loop jack passes along the signal received at the IR Remote In jack to the next compo nent which is IR controlled It is provided as a courtesy to make your installation easier and neater RS 232 Control Port This is used for linking your Zhd to your Parasound 7 1 Channel Surround Controller a comp...

Page 7: ...o depend on the quality of your HDMI cable and your HDMI source and receiving components You may need to experiment to determine if your particular setup benefits from the boost feature HDMI Boost selection is a one time setup operation which you won t need to change after your initial setup Note You may activate or de activate HDMI Boost only with the Input 1 and 5 buttons on the front panel not ...

Page 8: ...s chart C 1 and C 2 7100 HDMI Input Video 1 DVD 1 Video 2 SAT 2 Video 3 VCR 3 Video 4 IN 4 4 Video 5 IN 5 5 Video 6 IN 6 No control Remember you might have renamed the source input on your C 1 C 2 or 7100 Note If you require a different input selection from above you must operate the Zhd manually or program an IR macro into your system s master remote Note for Crestron or AMX users If the RS 232 p...

Page 9: ... your Parasound dealer first If the dealer can t help you with your problem we encourage you to call Parasound s Technical Service Department toll free at 1 866 770 8324 Monday Friday 8am 4pm Pacific time We can suggest other diagnostic tests you can easily perform If we determine that your Zhd should be returned to Parasound or an Authorized Parasound Warranty Center for inspection and possible s...

Page 10: ...e Parasound warranty is not transferable 3 Unit s serial number was removed modified or defaced 4 Unit shows evidence of abuse and or misuse 5 Unit was modified in any way 6 A prior repair was attempted by an unauthorized repair station AC Power Requirement 110 120 V 220 240 V 50 60 Hz 5 watts Dimensions 91 2 Wide 10 Deep with connectors 2 High with feet 13 4 panel only 241 x 254 x 50mm 44 1mm pan...

Page 11: ...NOTES Notes 9 ...

Page 12: ...Rev 0 92 Parasound Products Inc 2005 ...

Reviews: