b.  If the ULTRA UV unit is located above the water level of the pool or pond and 

the lamp(s) stay(s) lit when the pump is OFF, replace the pressure switch. 

THE WATER IS gREEN
 

 Green water is an indication that the UV rays generated by the ULTRA UV 
unit are not effective or are not being generated by the UV lamp(s).

 

a.  Check the lamp(s) to make sure all lamps in your system are ON (by 

viewing the lamp(s) through the clear viewing band on the center of the 
reactor. If all lamps are not ON, follow the procedures above regarding 
the UV lamp not lighting.

 

b.  Run your unit longer. If your unit is operating on a time clock, run the 

circulation pump longer to allow the ULTRA UV unit to function fully.

 

c. Clean the quartz tube(s).

 

d.  Replace the UV lamp(s) nearing the 13,000 hour useful lamp life. After 

13,000 hours of operation, the UV lamp(s) are only 80% as effective as 
when new. This is normal for all long life low-pressure type UV lamps, which 
are the longest useful life lamps available for this type of application.

 

e.  If your ULTRA UV unit is installed on a swimming pool, shock the pool 

with the sanitizing chemical you normally use and balance the pool 
water as per your chemical manufacturer’s specifications.

 

f.  Your unit is not sized for the flow and duration specific to your pool.

THE gFCI HAS TRIPPED
 

 If you have installed a GFCI on your ULTRA UV application, the GFCI will 
protect the ULTRA UV unit and any other equipment on the same electrical 
circuit from any fault to ground, the same as the electrical breaker 
protects the total electrical circuit from a short. When the GFCI trips, it 
is an indication that there is an electrical problem that must be corrected 
to provide a safe operating environment for your installation. Follow the 
instructions of the GFCI manufacturer for more information on correcting 
the issue if the problem is with the GFCI.

 

a.  If you suspect that the problem is with the ULTRA UV unit, disconnect 

the ULTRA UV unit from the electrical receptacle. Reset the GFCI at the 
breaker panel or at the receptacle. If the GFCI does not reset, have the 
G.F.C.I replaced by a licensed electrician. If the GFCI does reset, first 
run the circulation pump, and if no GFCI trip is encountered, plug the 
ULTRA UV unit into the electrical receptacle and make sure the pump 
is ON. If the GFCI trips, it is an indication that there is a ground fault 
inside the ULTRA UV unit. Follow the instructions previously given for 
opening the electrical enclosure cover and inspecting the ULTRA UV 
unit. Call a qualified technician. 

Summary of Contents for Ultra UV 004-422-2025-00

Page 1: ...precautions should always be followed including the following WARNING Follow all applicable electrical codes Turn off power at main source before making any electrical connections or servicing the un...

Page 2: ...ting The UV Unit On A Solid Base 6 Plumbing The Ultra UV Unit 7 Gluing Piping To The UV Unit 8 Providing Electrical Power To The Ultra UV Unit 8 Electrical Bonding Grounding 9 Pressure Switch 9 Connec...

Page 3: ...cm2 30 mJ Confirm the size unit your application needs by using the sizing charts on page 2 and 3 to obtain the proper maximum system killing power CAUTION DO NOT USE THIS UNIT FOR POTABLE DRINKING W...

Page 4: ...30V w 2 UV C Lamps w SS Reactor 004 422 2022 00 120V w 2 UV C Lamps 004 422 2029 10 1 20V w 2 UV C Lamps w SS Reactor 80 18 2 9600 36 3 14400 54 5 004 422 2027 00 230V w 3 UV C Lamps 004 422 2029 60...

Page 5: ...6 004 422 2026 00 230V w 2 UV C Lamps 004 422 2029 50 2 30V w 2 UV C Lamps w SS Reactor 004 422 2022 00 120V w 2 UV C Lamps 004 422 2029 10 1 20V w 2 UV C Lamps w SS Reactor 80 18 2 57600 218 0 38400...

Page 6: ...tra UV body The 4 outlets top and 4 inlets bottom provide the most versatile piping alternatives for the installer The Ultra UV unit comes with 2 each 2 inch or 63mm inlet and outlet unions Multiple i...

Page 7: ...and with bypass Plumbing the ULTRA UV units in a series for large bodies of water with excessive flow rates Figs 2a multiple port Plumbing Without and with bypass Be sure to use the appropriate amoun...

Page 8: ...te this voltage At 120V the power draw is 2 6 Amps maximum for a 4 lamp system This low power consumption makes operating your ULTRA UV unit very economical Your Ultra UV 120V unit is supplied with a...

Page 9: ...RLY Paramount Recommends you have this important work done by a Licensed Electrical Technician Pressure Switch The ULTRA UV unit is equipped with a pressure switch that does not allow the UV lamp s in...

Page 10: ...nded bypass valve then turn on the circulation system to ensure all debris is blown out of the plumbing Open the bypass and check for plumbing leaks and or leaks caused by damaged quartz tube Water Ch...

Page 11: ...p 2 allow at least 15 minutes for the bulbs in the unit to cool off 2 NEVER REMOVE THE ELECTRICAL ENCLOSURE COVER WITHOUT FIRST UNPLUGGING OR TURNING OFF THE CIRCUIT BREAKER POWER SOURCE FOR THE ULTRA...

Page 12: ...the way to get a better grip or to use a tool Remember to replace ballast 6 Carefully lift the compression washer from the top of the quartz tube making sure not to lose the black gasket that cushions...

Page 13: ...ube doing so can result in a leak and possible damage to your UV unit 10 To reinstall the quartz tube place the O ring 2 inches from the top of the outside of the quartz tube Fig 17 Place the quartz t...

Page 14: ...e of the black threaded sleeve and the quartz tube Check and make sure it is seated evenly around the circumference of the quartz tube Screw on the quartz sealing aluminum nut hand tight plus turn 13...

Page 15: ...d any body oils on lamp s Oils will create hot spots and greatly shorten lamp s life Carefully lift the lamp s from the quartz tube Fig 24 3 With the lamp s removed from the unit pull off the black bo...

Page 16: ...tures are considerably above freezing Option 2 Leaving the unit in place for the winter Turn off the power to the unit Remove the drain plug and allow all of the water to drain from the unit Disconnec...

Page 17: ...re Any Residual Effect From UV No All of the sanitizing is done in the reactor Can The Ultra UV Unit Be Mounted Horizontally No vertical mounting is required to maintain the weatherproof integrity of...

Page 18: ...f the breaker remove the enclosure cover on the top of the unit Move the wire on the pressure switch from the bottom post to the unused post on the top Turn on the power and if the lamps illuminate th...

Page 19: ...p life before the lamp s is are turned ON a If the top of a ULTRA UV unit is located below the water level of the pond or pool there is a static head of water that causes pressure to be found inside t...

Page 20: ...our chemical manufacturer s specifications f Your unit is not sized for the flow and duration specific to your pool The GFCI Has Tripped If you have installed a GFCI on your ULTRA UV application the G...

Page 21: ...place that ballast Refer to page 20 for the proper ballast part number Reset the GFCI and if it does not trip attach the electrical plug to a UV lamp One at a time if multiple lamps are present in you...

Page 22: ...lamp ballast 2 Lamp unit requires 1 dual lamp ballast 3 Lamp unit requires 1 single lamp ballast 1 dual lamp ballast 4 Lamp unit requires 2 dual lamp ballast 1 2 3 4 5 6 7 8 11 10 9 12 16 13 15 14 17...

Page 23: ...ivolt Ballast 1 Lamp 8 005 422 2009 01 Advance Intellivolt Ballast 2 Lamp 9 005 422 2009 10 Pressure Switch 10 005 422 9010 00 Ballast Mounting Bracket 11 005 422 2009 05 Pressure Gauge 12 005 422 200...

Page 24: ...MITATIONS No warranty extends to any part of the PP SS parts or components which is caused by any of the following conditions or events 1 Defects or failures caused by abuse lack of responsible care l...

Reviews: