15
SCHEDULED UV LAMP(S)
REPLACEMENT
The UV lamps have a useful life of
approximately 13,000 hours and
should be replaced at that time.
Even though the lamp(s) may be
glowing after 13,000 hours of
operation they have reached the
end of their useful life.
LAMP REPLACEMENT PROCEDURE
1. Refer to page 8, steps 1-3 before
removing lamp(s) (Fig. 23).
2. You must wear protective rubber
gloves to avoid any body oils on
lamp(s). Oils will create hot spots
and greatly shorten lamp(s) life.
Carefully lift the lamp(s) from the
quartz tube (Fig. 24).
3. With the lamp(s) removed from the
unit, pull off the black booties and
O-rings from the bottom of each
lamp(s) and remove the bottom
and top yellow aligning disk (Fig.
25, 26, 27). Retain both yellow
aligning disks. New replacement
lamp(s) includes black booties and
O-rings.
4. Discard lamp(s) appropriately.
Visit www.lamprecycle.org for
instructions on disposal. Repeat
the steps in reverse order to
reinstall the lamp(s).
Fig. 23
Fig. 24
Fig. 25
Fig. 26
Fig. 27