Make sure that wall plate (
A
) is level, use it as a
template to mark two mounting holes. Drill two 1/4"
(6 mm) dia. holes to a minimum depth of 2-1/2"
(64 mm). Insert anchors (
E
) in holes flush with wall
as shown. Place wall plate over anchors and secure
with two #14 x 2-1/2" screws (
D
). Level, then tighten
all fasteners.
Installation to Solid Concrete or Cinder Block
1
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in
a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet
ASTM C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole
instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
WARNING
CUT
A
W
A
Y
VIEW
INCORRECT
CORRECT
wall plate
plaster/
dry wall
concrete
wall plate
concrete
plaster/
dry wall
• Always attach concrete expansion anchors directly to
load-bearing concrete.
• Never attach concrete expansion anchors to concrete
covered with plaster, drywall, or other finishing mate-
rial. If mounting to concrete surfaces covered with a
finishing surface is unavoidable, the finishing surface
must be counterbored as shown below. Be sure
concrete anchors do not pull away from concrete
when tightening screws. If plaster/drywall is thicker
than 5/8" (16 mm), custom fasteners must be sup-
plied by installer (not UL approved).
WARNING
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
D
CINDER
BLOCK
SOLID
CONCRETE
A
E
concrete
surface
1
3
2
E
Drill holes and insert anchors (
E
).
Place plate (
A
) over anchors (
E
) and secure with screws (
D
).
Tighten all fasteners.
A
E
D