4

The use of two 45˚ in place of a 90˚ allows for the best debris removal 
and minimizes large debris from getting caught in the line.

MDX-R3 SYSTEM DESIGN

These MDX-R3 instructions provide two methods to choose from, with additional methods for 
specific jurisdictions, (California specifically but not limited to that state).  Your local codes may 
require additional safety measures. Paramount Pool & Spa Systems and its representatives cannot 
recommend or endorse installation methods other than those provided in these MDX-R3 instructions.

Maximum Pump Size:
MDX-R3 is rated for a maximum of 132 GPM (500 LPM). While system 
flow rate will vary with pump size and the Total Head Loss for a given 

system, virtually any modern pump is capable of exceeding this limit, therefore it is the responsibility of 
the system designer to make sure it is not possible to exceed 132 GPM (500 LPM). 

NOTICE

In the event of one suction outlet being completely blocked, the remaining suction outlets serving that 
system shall have a flow rating capable of the full flow of the pump(s) for the specific suction system.

NOTICE

MDX-R3 VGB COMPLIANT DEBRIS DRAIN

STANDARD POOL DESIGN

DUAL DRAIN

SDX2

2 1/2" MINIMUM

ENLARGED SUCTION ELEMENT

SECOND DRAIN

ANY ORIENTATION

2 1/2" TEE

2" OR LARGER

CIRCULATION LINE

NOTICE

Plumbing of the included enlarged suction element (13” of 
4” pipe) to the 4" port of the MDX-R3 is required. 

After the 

enlarged suction element, the included reducer adapter may then 

be used to reduce the pipe size to 2½”. A 3” coupler may be attached to the outside diameter   of 
the reducer or a 4” coupler directly to the enlarged suction element for systems where the flow 
through the MDX-R3 is intended to exceed 90 GPM. 

Use of 2½” pipe minimum throughout 

the suction side of the system is strongly encouraged for optimum performance. 

For 

your convenience, Paramount Pool & Spa Systems includes the enlarged suction element, and the 
reducer adapter with the MDX-R3. To order separately, please see page 12 for the part number.

NOTICE

Design Flow Rate = 132 GPM (500 LPM)
Maximum GPM = 132 (500 LPM)
Velocity at 132 GPM = 1.294 FPS (.39 MPS)

Summary of Contents for MDX-R3

Page 1: ...CIAL INSTRUCTIONS FOR CALIFORNIA ON PAGE 7 Safety compliant according to the Virginia Graeme Baker Pool and Spa Safety Act ANSI APSP 16 2011 Compliant with ANSI APSP 7 2006 WARNING MDX R3 and SDX2 mus...

Page 2: ...perly secured or missing because these conditions increase the chance of death or serious injury from entrapment If a drain cover is discovered damaged cracked broken loose clogged not properly secure...

Page 3: ...ety begins with a professional design that includes a quality suction system installed by a certified contractor Certified builders will address the following issues when designing and installing a pr...

Page 4: ...aining suction outlets serving that system shall have a flow rating capable of the full flow of the pump s for the specific suction system NOTICE MDX R3 VGB COMPLIANT DEBRIS DRAIN STANDARD POOL DESIGN...

Page 5: ...STER AND MV FUSE MV FUSE DECK SIDE SDX2 2ND SUCTION OUTLET 2 1 2 2 1 2 ENLARGED SUCTION ELEMENT IF NOT USING HYDROSTAT PLUG 2 PORT TRUNK LINE MUST BE SIZED TO MEET MAXIMUM VELOCITY REQUIREMENTS FOR SU...

Page 6: ...PER LOCAL CODE TO PUMP TO PUMP TRUNK LINE MUST BE SIZED TO MEET MAXIMUM VELOCITY REQUIREMENTS FOR SUCTION PLUMBING PER LOCAL CODE 2 1 2 OR 3 ENLARGED SUCTION ELEMENT METHOD 2 WITH DECK FUSE IF NOT USI...

Page 7: ...OR SUCTION PLUMBING PER LOCAL CODE TO PUMP EQUAL SIZE AND LENGTH FROM TEE TO EACH DRAIN SDX2 2ND SUCTION OUTLET CALIFORNIA INSTALLATION METHOD 1 WITH CANISTER WITHOUT MV FUSE IF NOT USING HYDROSTAT PL...

Page 8: ...aramount recommends the use of the 2 thread plug provided Do not use check valves here that are prone to sticking open causing the need to open the drain cover exposing a suction risk If a hydrostat i...

Page 9: ...location for the SDX2 drain Additional SDX2 drains may be used 2 For Steel Wall Make one 4 hole using a Greenlee Standard Round Knockout Punch Greenlee com Cat No 742BB UPC No 19978 For Plastic Wall...

Page 10: ...s without over tightening Fig 4 Fig 5 WITH CANISTER If vacuum relief suction outlets are located below freeze line skip steps 1 and 2 1 Remove grate from wall drain and install a 13 blow through plug...

Page 11: ...11...

Page 12: ...ug 4 with O Ring 11 2 Pipe Not Included Cap If Not Used 12 2 Cap Not Included Cap If Not Used 13 005 252 5524 00 Enlarged Suction Element 14 005 252 2550 00 Coupler Reducer 4 X 2 3 005 272 0841 00 Scr...

Reviews: