Replace cover within 05 installed years

MDX-R3 CONCRETE POOLS PART NUMBERS

Item 

Part Number 

Description 

005-252-2110-XX 

Cover (XX=Color Code)

 

Screw: No. 10 

1” Security Head 

005-252-8234-XX 

Funnel Assembly (Includes Support, Cover, Screw and Adapter)   

 

 

Screw: No. 12 X 1½” Flat Head

005-252-1045-00 

Funnel Adapter

005-252-2044-00 

Seal Ring

005-252-0010-00 

Gasket (2 pk)

005-252-1605-00 

Plug 2” NPT (6 pcs)

9  005-252-2024-00 Sump
10 

005-252-1610-00 

Plug 4” with O-Ring

11* 

 

2” Pipe - Not Included - Cap If Not Used

12* 

 

2” Cap - Not Included - Cap If Not Used 

13 

005-252-5524-00 

Enlarged Suction Element 

14 

005-252-2550-00 

Coupler Reducer 4” X 2½”/3”

005-272-0841-00 

Screw Pack Vinyl (19 pcs)

15 

005-252-2098-XX 

SDX2 Cover w/ Screws Vinyl/Fiberglass

16 

005-252-2061-00 

SDX2 Support Vinyl/Fiberglass

17 

005-252-0072-00 

SDX2 Gasket Set Vinyl/Fiberglass

18 

005-252-2035-00 

SDX2 Bulkhead Vinyl/Fiberglass 2 

½

”/3”

19 

005-252-2090-00 

SDX2 Bulkhead Nut

20 

005-252-0811-00 

SDX2 Screw Pack Complete for Vinyl & Fiberglass

21* 

005-252-0895-00 

T25 Security Screwdriver

* Not Part of MDX-R3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

21

15

16

17

18

19

20

Summary of Contents for MDX-R3

Page 1: ...CIAL INSTRUCTIONS FOR CALIFORNIA ON PAGE 7 Safety compliant according to the Virginia Graeme Baker Pool and Spa Safety Act ANSI APSP 16 2011 Compliant with ANSI APSP 7 2006 WARNING MDX R3 and SDX2 mus...

Page 2: ...perly secured or missing because these conditions increase the chance of death or serious injury from entrapment If a drain cover is discovered damaged cracked broken loose clogged not properly secure...

Page 3: ...ety begins with a professional design that includes a quality suction system installed by a certified contractor Certified builders will address the following issues when designing and installing a pr...

Page 4: ...aining suction outlets serving that system shall have a flow rating capable of the full flow of the pump s for the specific suction system NOTICE MDX R3 VGB COMPLIANT DEBRIS DRAIN STANDARD POOL DESIGN...

Page 5: ...STER AND MV FUSE MV FUSE DECK SIDE SDX2 2ND SUCTION OUTLET 2 1 2 2 1 2 ENLARGED SUCTION ELEMENT IF NOT USING HYDROSTAT PLUG 2 PORT TRUNK LINE MUST BE SIZED TO MEET MAXIMUM VELOCITY REQUIREMENTS FOR SU...

Page 6: ...PER LOCAL CODE TO PUMP TO PUMP TRUNK LINE MUST BE SIZED TO MEET MAXIMUM VELOCITY REQUIREMENTS FOR SUCTION PLUMBING PER LOCAL CODE 2 1 2 OR 3 ENLARGED SUCTION ELEMENT METHOD 2 WITH DECK FUSE IF NOT USI...

Page 7: ...OR SUCTION PLUMBING PER LOCAL CODE TO PUMP EQUAL SIZE AND LENGTH FROM TEE TO EACH DRAIN SDX2 2ND SUCTION OUTLET CALIFORNIA INSTALLATION METHOD 1 WITH CANISTER WITHOUT MV FUSE IF NOT USING HYDROSTAT PL...

Page 8: ...aramount recommends the use of the 2 thread plug provided Do not use check valves here that are prone to sticking open causing the need to open the drain cover exposing a suction risk If a hydrostat i...

Page 9: ...location for the SDX2 drain Additional SDX2 drains may be used 2 For Steel Wall Make one 4 hole using a Greenlee Standard Round Knockout Punch Greenlee com Cat No 742BB UPC No 19978 For Plastic Wall...

Page 10: ...s without over tightening Fig 4 Fig 5 WITH CANISTER If vacuum relief suction outlets are located below freeze line skip steps 1 and 2 1 Remove grate from wall drain and install a 13 blow through plug...

Page 11: ...11...

Page 12: ...ug 4 with O Ring 11 2 Pipe Not Included Cap If Not Used 12 2 Cap Not Included Cap If Not Used 13 005 252 5524 00 Enlarged Suction Element 14 005 252 2550 00 Coupler Reducer 4 X 2 3 005 272 0841 00 Scr...