5
SELECTING LOCATION & MOUNTING UNIT
1. Select a location on a wall near the pool
equipment or insert posts into the ground,
which will be used to hang unit. The Clear O3
®
unit should be at least one (1) foot above
maximum water level, and for extra safety
the unit must be mounted higher than the
filter. The unit should be within five (5) feet of
an electrical source, and within nine (9) feet
of plumbing connection. Mounting brackets
are horizontally adjustable to line up with hard
points on the mounting surface. The unit must be
mounted horizontally and level on the wall. Electrical
connections should be facing downward.
2. Use provided screws and plastic wall inserts
or poles and pole mount clamps (not included)
depending on installation surface available.
3. Four (4) mounting brackets are included (two for the
top slot and two for the bottom slot.
4. Install anchors and screws in desired location for
the top hangers. They must be no further apart than
twelve (12) inches. Do not tighten screws all the
way. (Fig. 1)
5. Hang the Clear O3 from the two top brackets by
sliding the keyhole slots over the screws.
6. Mark the location for the two bottom brackets. (Fig.
2)
7. Remove the Clear O3 from the wall and install the
wall anchors.
8. Place the Clear O3 unit back on the screws and
line up the two lower brackets with the wall anchors.
(Fig. 3)
9. Install the bottom two screws and tighten all
screws.
Fig. 2
Fig. 3
12" Maximum
Fig. 1