background image

18

[Attaching]

Insert the mounting section into the option

attachment hole as shown in the picture.

Turn the lever to fasten the calf supports.

Lightly lift the calf supports and make sure that it 

is fastened.

4.Attaching / detaching the calf supports

[Detaching]

Turn the lever to loosen.

Lift the calf supports as shown in the picture.

Fasten the lever when the calf supports are mounted in the option attachment holes. Otherwise, the 

calf supports may drop, causing an injury.

The calf supports can be used when examining the patient or giving birth.  

Mounting section 

Option attachment hole

Main frame side label

Mounting section label

Summary of Contents for Celenus PD-200 Series

Page 1: ...thority of the member country of residence Serious incident means any incident that directly or indirectly led might have led or might lead to any the following a The death of a user carer or other pe...

Page 2: ...in 1 Using Emergency CPR back lowering function BEDSIDE TABLE 15 16 19 24 31 34 35 36 37 38 40 41 42 43 44 49 50 51 CONNECTING TO THE POWER SUPPLY 1 Power outlets 2 Using the cable storage hook OPERAT...

Page 3: ...section base Hip section base Power plug Battery unit Main frame Base frame Caster Fluid basin Hand grip attachment hole Option attachment hole Caster operation pedal p 16 p 15 p 17 p 18 31 p 19 29 p...

Page 4: ...served Indicates actions that may result in death or serious injury broken bones pressure or paralysis if the indication is ignored Indicates actions that may result in light personal injury bruises w...

Page 5: ...utions requiring special attention by persons using the bed are affixed as pictured in the figure If the safety label is removed or defaced replace it with a new one obtained from your dealer 4 Safety...

Page 6: ...the body to enter the gap in the side rail and the board If the bed is operated with a body part placed in the gap the part may get caught resulting in injury When the head or neck enters the gap the...

Page 7: ...rea or temporarily taking your eyes off the patient check the mattress base angle bed height and the side rail status If a physician nurse or caregiver leaves the bed area or temporarily takes their e...

Page 8: ...ent s medical condition Do not attach a restraint belt Otherwise it may cause an injury or bed damage or deformation Do not stand on the bed There is a risk of injury caused by the person falling off...

Page 9: ...n unexpected injury When moving the bed operate the caster operation pedal and unlock the casters Do not step on the caster operation pedal There is a risk of injury due to falling or damage to the be...

Page 10: ...sing a dry cloth Always unplug the power plug before cleaning There is a risk of injury due to accidental operation or electric shock due to a short circuit Do not insert or remove the power plug with...

Page 11: ...due to short circuit or current leakage from electrical parts or injury due to malfunctioning caused by deformation of the bed The bed should not be used by two or more persons This bed is designed fo...

Page 12: ...n Do not sleep face down If the patient sleeps face down for a prolonged time there is a risk of asphyxiation because the mattress cover is not breathable Do not spray a spray type insecticide directl...

Page 13: ...ed or may cause the bed to be damaged or deformed Do not get on the mattress base when it is raised Excessive force on the mattress base can cause damage or deformation Check the surroundings before o...

Page 14: ...it as slowly as possible The handheld controller must be attached to the appropriate bed If it is attached to an inappropriate bed the bed could operate unexpectedly resulting in injury or bed failur...

Page 15: ...mperature 5 to 40 Humidity 20 RH to 90 RH Atmospheric pressure 700hPa to 1060hPa Locations with large amount of dust smoke salt sulfur or corrosive substances Locations with poor ventilation Locations...

Page 16: ...oard could be rattled or come off resulting in injury When removing the board do not forcefully lift it while the board is tilted There is the risk of deformation of the board insertion parts Attachin...

Page 17: ...in receivers as shown in the picture Mount the fluid basin on the fluid basin receivers fluid basin receiver fluid basin Detaching Lift and detach the fluid basin Push in the fluid basin receivers as...

Page 18: ...osen Lift the hand grip as shown in the picture 3 Attaching detaching the hand grips Be careful not to allow any part of the body to enter the gap between the hand grip and the mattress base the side...

Page 19: ...ching detaching the calf supports Detaching Turn the lever to loosen Lift the calf supports as shown in the picture Fasten the lever when the calf supports are mounted in the option attachment holes O...

Page 20: ...f the control box and slide the control box cover to open it Connect the battery cable to the battery adapter of the control box Attach the control box cover When connecting the battery cable unplug t...

Page 21: ...y wired single phase 230VAC 10A or greater grounded power outlet using the power plug Never connect more than one cable to a power outlet 2 Using the cable storage hook Wind the power cable onto the c...

Page 22: ...ectrically from 50cm to 83cm Do not allow the patient to get on or off the bed while the bed is tilted There is a risk of injury due to the patient falling down Tilting the bed must only be performed...

Page 23: ...ted injury such as the body getting caught in the bed by mistake If such person can come into contact with the handheld controller unplug the power plug in order to prevent accidents caused by incorre...

Page 24: ...tly Request repair or replacement of a damaged handheld controller The handheld controller must be properly set in the storage position or hung on the side rail with the buttons facing outwards using...

Page 25: ...the back section base and either lever can be used Keep pulling the lever until the back section base returns to flat status If you release the emergency CPR lever halfway through the back lowering o...

Page 26: ...se and make sure that it is locked Place the foot mattress on the leg section base Leg section base Leg section retraction lever Lift Retracted position Do not sit on the leg section base Otherwise th...

Page 27: ...ection This makes it easier for the bed to be moved forward in a straight line Unlocking the four wheels Free position Returning the pedal to the horizontal position unlocks the four wheels allowing t...

Page 28: ...sing the side rails Lift the side rail and push in until it clicks into place Pull the side rail toward you to make sure that the side rail is locked Lowering the side rails Use one hand to hold the g...

Page 29: ...g side rails make sure that the side rails are locked If the side rails are not completely locked they may move unexpectedly resulting in injury Take care to prevent the intravenous tubes or the drain...

Page 30: ...with the bed turned upside down Operating the bed on battery power The bed is powered by the battery when the power plug is not connected to the power outlet or during a power failure Recharging Recha...

Page 31: ...e to an angle that exceeds 30 as far as possible If an angle of 30 is exceeded pressure friction and shear forces will be applied to the patient s hips and buttocks which may cause pressure sores If c...

Page 32: ...uct due to specification changes For any queries please feel free to contact your dealer 1 Foot rest PC 5051 PC 5054 PC 5064 The foot rest can be used during delivery Be careful not to allow any part...

Page 33: ...n not to touch the fluid basin Otherwise the fluid basin may be tipped over accidentally The doctor can use the foot support bar 2 Foot support bar PC 5052 The description in this instruction manual m...

Page 34: ...be used by hanging it on the head board Hang the oxygen cylinder holder on the head board Loosen the knob bolt on the oxygen cylinder holder and then slowly insert the oxygen cylinder into the holder...

Page 35: ...hand or arm between the mattress base or the head board and the IV pole The hand or arm may get caught resulting in injury Each hook s load capacity is 1 kg Do not hang an article exceeding the load...

Page 36: ...e bed Otherwise the patient may get caught between the table and the bed and may get injured The bedside table can be used as a table for meals or other activities when on the bed The description in t...

Page 37: ...tus steering position AC input Take care to prevent body parts from getting caught in the moving parts on the bed IPx4 Protection code Take care to prevent the patient s head from getting caught in th...

Page 38: ...ey are locked Do not sit on the leg section base The medical bed for adults Model number Country of manufacture Made in Indonesia Medical device This product is a medical device or an accessory for me...

Page 39: ...egible Board Board mounting condition p 15 The board stopper must be locked properly There must not be any remarkable rattling Operation details Inspection items Bed Unit Back raise operation p 21 to...

Page 40: ...Please feel free to contact your dealer to be lubricated Water adhesion to the bed or the mattress or moisture may cause corrosion abnormal noise or contamination If water adheres to the bed or the m...

Page 41: ...the fastener and do not remove the cover when cleaning and disinfecting the mattress Do not unzip the fastener while the mattress is in use The fastener is provided so that the cover can be repaired o...

Page 42: ...tive action Refer ence page The bed does not move even when the handheld controller buttons are pressed Check if the power plug is plugged into the outlet Plug the power plug into the outlet 20 The po...

Page 43: ...oard Hand grip Head Mattress Foot Mattress Product ID label Product ID label Product ID label Fluid basin Product ID label Calf support Product ID label Product lifetime The lifetime of this equipment...

Page 44: ...to be exposed to high temperatures high humidity low temperatures dry or dusty conditions Store at a temperature between 10 and 50 humidity between 20 RH and 90 RH and atmospheric pressure between 700...

Page 45: ...ial Side rail Made of steel powder coating part is resin mold item Particle board Bed inclination Inclination angle Time required 0 to 12 2 0 13sec 4 Height adjustment Height range Time required 330mm...

Page 46: ...index BMI 45 Essential performance Function to support the body of patient Emergency CPR back lower function Frequently used functions Back raising height adjustment trendelenburg side rail raising a...

Page 47: ...for use in the electromagnetic environment specified by electromagnetic disturbance of bed The following abnormality may occur if using bed in unintended environment The function for supporting patie...

Page 48: ...4 EN 61000 4 4 2kV power supply line 2kV power supply line Surge IEC 61000 4 5 EN 61000 4 5 Line line 0 5kV 1 0kV Line ground 0 5kV 1 0kV 2 0kV Line line 0 5kV 1 0kV Line ground 0 5kV 1 0kV 2 0kV Shor...

Page 49: ...low Enclosure port to RF wireless communications equipment IEC 61000 4 3 EN 61000 4 3 27V m 385MHz 27 380 390 TETRA 400 9V m 710MHz 9 704 787 LTE Band 13 17 28V m 1720MHz 28 1700 1990 GSM 1800 CDMA 19...

Page 50: ...he compliance level of the respective frequency band Near devices with the following symbol interference could occur 49 a The intensity of a magnetic field from fixed transmitters such as a radio mobi...

Page 51: ...el number see p 42 Date of purchase Details of fault or problem please provide as much details as possible Your name organization address and phone number Consumable parts The mattress casters handhel...

Page 52: ...A BARAT INDONESIA Tel 62 0 21 8981051 FAX 62 0 21 89981611 51 When the PD 200 Electric delivery bed has reached the end of its usable life discard it according to local standards Bed disposal For any...

Page 53: ......

Page 54: ......

Page 55: ......

Page 56: ...2021 04...

Reviews: