Auto-Zero
The Auto-zero Timeout will set the account to zero after this time has elapsed. This
is useful if you are using confirmed uplinks. If the uplinks fail, the counter will be
reset to zero after this time.
Default: 120min
Totalizer
This setting defines how to increment the counter values.
Totalizer
Counter
Reset
Disabled
Counter values represent
object counts during
the
last time period
After a LoRaWAN Uplink
ACK is received the counter
values are cleared.
Enabled
Counter values start with
0 and go up to 65535
max.
Reset counters with
a LoRaWAN Downlink
Command
Default: Disabled
Fallback Category
We try to measure object size and speed. In some situations, however, it is not
possible to determine the size and speed in addition to the direction of movement.
This is mainly if the object is too fast or covers the field of view (FOW). In this
cases, no classification into categories is made and instead the counter of
the
fallback category
is increased.
Try to place the sensor a little further away from the object so that the objects fits
into the FOW.
Traffic Categories
Criteria defining each type of detection. The radar determines the category based
on the speed and size of the object.
Low Speed device: You can only select two categories (People and Two-Wheelers)
High Speed device: You can select all 4 categories (People, Two-Wheelers, Cars,
HGV)