12
LT5245 (2:02/09)
Paragon Symphony CF
Installation Instructions
SECTION SIX
Appliance Data
NATURAL GAS
Gas Type:
CATEGORY I 2 H
Gas Pressure:
20 mbar +/- 1.0mbar
Pressure Test Point Location:
Gas inlet elbow
Gas Input:
5.5 kW Gross (Max.)
2.4kW Gross (Min.)
Injectors:
Mk 360
Oxy pilot:
9102
Gas Connection:
8mm compression: semi-rigid or rigid
Data Badge Location:
Located on the right hand side of the appliance behind the trim and
fascia.
Battery
Remote handset 9v size MN1604 or 6F22,
Appliance 6 x 1.5V AA high power alkaline or 6 x 1.5 V Rechargeable nickel metal
hydride with a minimum capacity of 2200mAh.
A special long life lithium battery 7.2 V is available as an optional extra.
Appliance Dimensions
NOTE: The efficiency of this appliance has been measured as specified in BS7977-1 2002 and the
result is 80%. The gross calorific value of the fuel has been used for this efficiency calculation.
GasTec have certified the test data from which it has been calculated. The efficiency value may be
used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings.
When unpacking the appliance please check the following items are included:
Fuel Bed:
Air Tray
Owners Manual
Vermiculite
Trim
Cerrowool
Fascia.
Summary of Contents for SYMPHONY CF
Page 23: ...23 LT5245 2 02 09 ...