MIM2-A2-GZ40-00
October 2004
7
LED Indicators
Regulatory Notices
UNITED STATES – EMI NOTICE:
!
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC rules. These limits
are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
The authority to operate this equipment is conditioned by the
requirements that no modifications will be made to the equipment
unless the changes or modifications are expressly approved by
Paradyne Corporation.
Table 1. LEDs
LED
STATE
INDICATION
ADDITIONAL INFORMATION
E1 Connections
(Port 1 Lnk and
Port 2 Lnk)
Flashing Green*
E1 connection is established and
active.
Traffic is flowing.
Solid Green
Problematic E1 connection.
A connection exists but there is
indication of a problem with the E1 line.
No Illumination
Loss of Synchronization
(LOS)The incoming connection
to the MIM-2E1 has been lost;
no data is being received.
If the outgoing connection from the
MIM-2E1 has also been lost then the
remote E1 equipment to which the MIM
is connected will have LOS as well.
E1 Alarms (Port 1
Alm and Port 2
Alm)
No Illumination
E1 is operational.
An established E1 link is operational
and has no alarm indications unless the
E1 Lnk LED remains unlit as well, in
which case the MIM-2E1 has LOS.
Solid Amber
Remote Alarm Indication (RAI).
The outgoing connection from
the MIM-2E1 has been lost; no
data is being transmitted.
The remote E1 equipment has lost its
incoming connection and has LOS.
Pulsing Amber*
Alarm Indication Signal (AIS). An
indirect connection has been
lost; the MIM-2E1 may no longer
be receiving data from the
remote E1 equipment.
The remote E1 equipment has lost a
connection with an intermediate device
and has LOS or RAI.
*
A pulsing LED blinks steadily at a rate of once per second. A flashing LED blinks at a more rapid,
less constant rate.
!