Customizing G.703-Compatible Units
4-2
7915-A2-GB20-20
September 1997
Enter “?” to redisplay the menu.
The CP unit is also known as an SDSL Termination Unit - Remote (STU-R). A
unit on the CO side is an SDSL Termination Unit - Central (STU-C). Option 6
on the Main Menu varies according to unit type: on a CO unit it is used to
monitor the CP unit (STU-R) and on a CP unit it is used to monitor the CO
(STU-C).
This guide depicts the system terminal menus as they appear from a CP unit
(unless otherwise noted). This is the default configuration for Model 7915
standalone units.
Making Changes from the Terminal Interface
The Board Configuration menu displays the current board software and hardware
settings. It also allows you to change certain parameters on the board.
This function is affected by the status of the switchpack (DIP switch control)
setting.
When operating in Terminal Mode (the system default) you can make
configuration changes through the terminal menus.
When operating in Switchpack Mode, you can display configuration
parameters using the terminal menus, but any configuration changes must be
made using the switchpacks on the board hardware. Refer to
Making
Changes in Switchpack Mode
on page 4-5.
From the Main Menu, select option 3, Board Configuration.
The following example shows the menu that appears on a CP unit.
Command
→
3
Board Configuration:
–––––––––––––––––––
1) SDSL Card Type
– CP
SDSL Rate Type
– E1
2)
E1 Line Encode
– HDB3
3)
Framing
– Framed
SDSL FW Rev
– 02
Globespan FW Rev
– 1.07
CP Serial #
– 088165
–––––––––––––––––––––––––––––––––––––––––––––––––––––––
1–3)
Board Configuration
4)
Switchpack Definitions
?)
Prints Board Configuration and this menu
Q)
Quit
Config
→