3
6038 MVL POTS Filter Technical Specifications
Item
Specification
*
Height x Width x Depth
1.02
″
x 1
″
x 2.5
″
(2.6 cm x 2.5 cm x 6.4 cm)
Weight
2.1 ounces (59.5 grams)
Approvals
Refer to the equipment’s label for the FCC Part 68
Registration Number and Safety Certifications.
Physical Environment
Operating temperature
Storage temperature
Relative humidity
Shock and vibration
0
°
F to 140
°
F ( 32
°
C to 60
°
C )
– 40
°
F to 158
°
F ( – 40
°
C to 70
°
C )
5% to 95% ( noncondensing )
Withstands normal shipping and handling
Interface Connectors
Two 6-pin, non-keyed RJ11 modular jacks
*
Technical Specifications subject to change without notification.
Important Safety Instructions
1. Read and follow all warning notices and instructions marked on the product or
included in the manual.
2. This product is intended to be connected to Listed/Certified telephone wiring
behind a Listed/Certified primary protector. Use the supplied cable.
3. Do not attempt to service this product yourself, as opening or removing covers may
expose you to dangerous high-voltage points or other risks. Refer all servicing to
qualified service personnel.
4. When installed in the final configuration, the product must comply with the
applicable Safety Standards and regulatory requirements of the country in which it
is installed. If necessary, consult with the appropriate regulatory agencies and
inspection authorities to ensure compliance.
Notice to Users of the Telephone Network
This equipment complies with Part 68 of the FCC rules. On the bottom of the
equipment’s enclosure is a label that contains, among other information, the FCC
registration number and ringer equivalence number (REN) for this equipment. If
requested, this information must be provided to the telephone company.
This equipment is designed to be connected to the telephone network or premises
wiring using compatible modular plugs and jacks which are Part 68 compliant. Use the