background image

 9

2. Use an 8-pin Ethernet crossover cable for the Ethernet connection. Insert one end

of the cable into the jack labeled ETHERNET. Connect the other end to the
Ethernet Network Interface Card (NIC) installed in the PC.

00-15303b-01

PC with Ethernet

Network Interface

Card

Ethernet

Line

POWER

ETHERNET

DSL

Hotwire RTU

Ethernet

Crossover

Cable

For RTU cable pin assignments, refer to 

Cables & Connectors on page 12.

3. Insert the supplied power cord’s round end into the jack labeled POWER. Plug the

transformer into an AC outlet.

98-15837

POWER

ETHERNET

DSL

Hotwire RTU

Power

Jack

Transformer

or

The RTU hardware installation is now complete. When the power cord is installed, the
RTU goes through a power-on self-test.

Summary of Contents for Hotwire 5216

Page 1: ...cess over traditional twisted pair copper telephone wiring Copper pairs run from the central office CO to the customer premises CP to create the local loop The local loop terminates on the customer pr...

Page 2: ...omer Premises CP DSL Ethernet Crossover Cable Central Office CO Demarcation Point Local Loop End user System DSL Digital Subscriber Line RTU Remote Termination Unit NID Network Interface Device New Wi...

Page 3: ...ider DSL Access with a Hotwire 5038 Distributed POTS Splitter When a Hotwire 5038 Distributed POTS Splitter is used one 5038 Distributed POTS Splitter is installed as a phone filter for each telephone...

Page 4: ...ckage Checklist Verify that your package contains the following Model 5216 Remote Termination Unit RTU DSL interface cable with RJ11 modular plugs Power cord with power transformer Wiring and Cables Y...

Page 5: ...esidential locations Procedure 1 Access the punchdown block or NID 2 Disconnect the DSL access pair from the local loop WARNING Do not continue unless the DSL access line from the local loop has been...

Page 6: ...n the following example a NID is used without a POTS splitter It includes an existing POTS line and a second pair installed for DSL access DSL POTS Access from Local Loop Wiring to DSL Jack Telephone...

Page 7: ...7 15343 02 DSL RJ11 Jack Central Office Punchdown Block or NID Customer Premises POTS DSL Local Loop Demarcation Point DSL Twisted pair Wiring RTU Procedure 1 Wiring can be run from the punchdown bloc...

Page 8: ...lled on the same line as POTS a Hotwire 5038 Distributed POTS Splitter can be used as a phone filter One 5038 Distributed POTS splitter is installed as a phone filter for each telephone on the POTS DS...

Page 9: ...Interface Card Ethernet Line POWER ETHERNET DSL Hotwire RTU Ethernet Crossover Cable For RTU cable pin assignments refer to Cables Connectors on page 12 3 Insert the supplied power cord s round end in...

Page 10: ...ing the power on self test After a successful self test the LEDs should appear as indicated in BOLD in the Condition column below LED Condition Status PWR ON The RTU has power ALM OFF ON No active ala...

Page 11: ...minutes contact the service provider DSL LED is on and there is no data transmission The DSL link has been established but there is no data transmission Verify the Ethernet connection If the problem p...

Page 12: ...2 Not used 3 DSL Ring 4 DSL Tip 5 6 Not used Ethernet interface crossover cable connector uses an 8 pin non keyed modular plug 10 100BaseT TX D 10 100BaseT TX D 10 100BaseT RX D Not Used Not Used 10...

Page 13: ...nd 3 16 drill bit for the molly bolts Screwdriver A template with the dimensions for the three screws is provided See RTU Hardware Template on page 14 Procedure To mount the RTU 1 Use a drill to insta...

Page 14: ...14 RTU Hardware Template Front LEDs 98 16171 5 43 7 55 To Bottom Hole...

Page 15: ...SPR 22 Safety Certifications Class B Subpart B digital device Class B Refer to equipment s label for approvals on product Physical Environment Operating temperature Storage temperature Relative humidi...

Page 16: ...ction authorities to ensure compliance 7 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in separate buildings are interconnec...

Page 17: ...ause undesired operation The name address and telephone number of the responsible party is given below Paradyne Corporation 8545 126th Avenue North Largo FL 33773 1502 Phone 727 530 2000 The authority...

Page 18: ...ctions United States Notice to Users of the Telephone Network 1 This equipment complies with Part 68 of the FCC rules On the equipment is a label that contains among other information the FCC registra...

Page 19: ...commission or corporation commission for information 9 An FCC compliant telephone cord with modular plugs may be provided with this equipment This equipment is designed to be connected to the telephon...

Page 20: ...butor locations or Paradyne worldwide office locations use one of the following methods H Internet Visit the Paradyne World Wide Web site at www paradyne com Be sure to register your warranty at www p...

Reviews: