background image

 23 

Connecting to the DTE

1. Connect one end of the DTE’s V.35 cable to the data port.

2. Plug the other end of the cable into the DTE.

3. Tighten the screws on each side of the connector to secure them.

POWER

COM

NETWORK

DSX-1

98-15828

(FrameSaver 9124

Shown)

DTE

If installing a FrameSaver 9128, repeat this procedure for the second port.

Verification Check:

Is the port OK LED on?

– If yes, the port is ready to communicate.
– If no, check that both ends of the V.35 cable are properly seated and secured.

Check Health and Status messages in the left column of the System and Test
Status screen for messages.

Main Menu

Status

System and Test Status

– If System Operational appears, the Port-1 interface is set up correctly and

is operational.

– If System Operational does not appear, refer to the status information in

Displaying System Information of the User’s Guide.

NOTE:

When any error conditions are detected, a status message will appear at the
bottom right corner of the screen.

If installing a FrameSaver 9126 or 9128, proceed to 

Connecting to the ISDN

on page 26 if the unit is equipped with an ISDN DBM. Otherwise, proceed to
Connecting to the Modem on page 25.

Summary of Contents for FrameSaver SLV Series

Page 1: ...A2 GB20 FrameSaver SLV 9x24 User s Guide 9128 A2 GB20 FrameSaver SLV 9126 9128 User s Guide To request a paper copy of a Paradyne document Within the U S A call 1 800 PARADYNE 1 800 727 2396 Outside t...

Page 2: ...OTE It is important that you follow the instructions for installing the FrameSaver unit as they are presented if you are to have a quick and trouble free installation Do not install your cables until...

Page 3: ...May Need to Order FrameSaver SLV units have native interfaces so cables are readily available with the following exceptions If connecting to a Order a Model Feature Number T1 Line interface connector...

Page 4: ...curely into the jack POWER COM NETWORK DSX 1 98 15823 Power Cord Transformer Insert the 3 prong plug into an ac outlet O K A L M The front panel OK LED lights 2 3 3 Prong Grounded AC Outlet Locking Ta...

Page 5: ...cable into the FrameSaver unit s COM port 98 15824 POWER COM NETWORK DSX 1 To Connect to a PC or Async Terminal COM Port FrameSaver 9124 Shown 3 Insert the other end of the cable into the VT100 compat...

Page 6: ...is not lit LED is burned out Run the Lamp Test If the LED in question does not flash with the other LEDs contact your sales or service representative Power Up Self Test fails The Alarm LED is on after...

Page 7: ...arrow key twice so the cursor is on Configuration 2 Press Enter to display the Configuration menu The Load Configuration From menu appears 3 Press Enter to select Current Configuration The cursor is a...

Page 8: ...ou connect the cables first Verifying that Self Test Passed Before starting to configure the FrameSaver unit confirm that the unit passed the self test 1 Follow this menu selection sequence from the M...

Page 9: ...trap managers Set up service provider connectivity NOTE Follow these instructions as they are presented Installation time will be increased if you connect the cables first Setting the System Clock To...

Page 10: ...which is the default setting Configuration Time Slot Assignment Frame Relay Network Assignments This feature can be disabled if desired so that Frame Relay to Network Time Slot Assignments can be man...

Page 11: ...tion Edit Display menu Setting Up Data Ports 1 Configure the physical characteristics of the port Configuration Data Ports Physical 2 For multiport FrameSaver units select a port Helpful Hint Press th...

Page 12: ...Setup of the User s Guide for additional information If trap dial out is desired 1 Set up the modem call directory phone numbers Main Menu Control Modem Call Directories 2 Select the desired Director...

Page 13: ...ure a Link Profile for the central site in the first link profile called HQ_Site This ensures that a backup DLCI will be created on the backup link for each DLCI discovered on the network interface us...

Page 14: ...Step 11 7 Save the configuration and return to the ISDN menu 8 Select DLCI Records New and press Enter Minimally configure the following options to create DLCI records for the link DLCI number DLCI T...

Page 15: ...r the data port Configuration Data Ports DLCI Records 2 Save the configuration and return to the Configuration Edit Display menu 3 Select Management PVC Configuration Management and Communication Mana...

Page 16: ...each DLCI discovered on the network a multiplexed network DLCI and a standard port DLCI will be configured and connected EDLCI 0 creating a PVC within the FrameSaver unit No management DLCIs will be...

Page 17: ...Records screen Configuration Network DLCI Records Connecting to the Network 1 Insert the 8 pin connector of the network cable into the network interface If a FrameSaver 9124 9126 or 9128 it is a RJ48...

Page 18: ...fer to the status information in Displaying System Information of the User s Guide for possible reasons for the messages and what can be done to resolve the problem Verification Check for a FrameSaver...

Page 19: ...ustomer s central site and the NOC console This requires that a frame relay discovered DLCI needs to be modified This is because all auto configured network DLCIs are configured as multiplexed DLCIs T...

Page 20: ...select Start NOTE When running tests the cursor is positioned over the Start command Press Enter to start the test Stop is displayed while the test is running Press Enter again to issue the Stop comma...

Page 21: ...ay PVC Problems in Troubleshooting of the User s Guide 4 Put the central site into PVC Loopback taking frames from the PVC and looping them back Main Menu Test Network PVC Tests DLCI Number PVC Loopba...

Page 22: ...he other end of the DSX cable to the CPE 4 Tighten the screws on each side of the connector to secure them Verification Check Check the DSX LEDs Is the Sig DSX 1 signal LED on and are the DSX 1 OOF ou...

Page 23: ...seated and secured Check Health and Status messages in the left column of the System and Test Status screen for messages Main Menu Status System and Test Status If System Operational appears the Port...

Page 24: ...isplayed See Displaying System Information in the User s Guide for additional status information and Troubleshooting for additional troubleshooting information Check PVC Connections Check PVC connecti...

Page 25: ...PC and verify that the Main Menu appears If Port Use is set to Net Link SNMP Telnet FTP and trap dial out dial the modem s phone number using a PC running PPP or SLIP link protocol and run the IP Ping...

Page 26: ...correctly Check backup setup Have someone disconnect the network cable at the remote site Check the status of the FrameSaver unit Main Menu Status System and Test Status Health and Status column Wait...

Page 27: ...st been reset or an error or fault has been detected OFF No failures have been detected TST Test Mode Yellow ON Loopback or test pattern in progress initiated locally remotely or from the network OFF...

Page 28: ...F No alarm condition is present on the Network DSX PRI interface FrameSaver 9624 DM Data Mode Green ON FrameSaver unit is sending or receiving data or is in DMI data mode idle an all 1 s condition OFF...

Page 29: ...sent from the DTE over interchange circuit BA ITU 103 is all 1 s OFF Data sent from the DTE over interchange circuit BA ITU 103 is all 0 s Blinking ON and OFF Rate 5 Hz Both 1 s and 0 s are being rece...

Page 30: ...cations Specification Criteria Approvals FCC Part 15 FCC Part 68 Industry Canada Safety Class A digital device Refer to the equipment s label for the Registration Number Refer to the equipment s label...

Page 31: ...2 F to 122 F 0 C to 50 C 4 F to 158 F 20 C to 70 C 5 to 85 noncondensing Withstands normal shipping and handling COM Port Interface Communications Management Standard Data rates 8 position modular jac...

Page 32: ...9128 Physical interface FrameSaver 9126 Physical interface Framing format Coding format DTE line equalization Send AIS 15 position D Subminiature connector D Sub 15 socket 8 position modular connector...

Page 33: ...ice supported Data rates Framing format Coding format Line Build Out LBO ANSI PRM ISDN PRI interface One 8 position modular unkeyed USOC RJ48C jack RJ48C PRI NI 2 ATT 4ESS custom or ATT 5ESS custom su...

Page 34: ...be installed in accordance with the card installation instructions WARNING To Users of Digital Apparatus in Canada This Class A digital apparatus meets all requirements of the Canadian interference c...

Page 35: ...regulatory agencies and inspection authorities to ensure compliance 8 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in sepa...

Page 36: ...that can be connected to the line as determined by the total RENs contact the local telephone company If your unit causes harm to the telephone network the telephone company may discontinue your servi...

Page 37: ...wing Service Order Code 6 0F Facility Interface Code 04DU 1SN Up to 23B Service for an ISDN PRI DBM Supports up to 23 circuit switched B channels with one local phone number for the entire T1 network...

Page 38: ...f the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions may not prev...

Page 39: ...a fax or to speak with a company representative Within the U S A call 1 800 870 2221 Outside the U S A call 1 727 530 2340 Document Feedback We welcome your comments and suggestions about this documen...

Reviews: